1992
DOI: 10.1016/0003-2697(92)90460-o
|View full text |Cite
|
Sign up to set email alerts
|

Detection and molecular weight determination of polyethylene glycol-modified hirudin by staining after sodium dodecyl sulfate-polyacrylamide gel electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
137
0
1

Year Published

2001
2001
2021
2021

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 202 publications
(144 citation statements)
references
References 12 publications
6
137
0
1
Order By: Relevance
“…Although PEG could be quantified in PEG-containing control samples, the PEG concentration within the final HEK293T-CD63-eGFP EV samples (clone B2 and C5 EVs were tested) was below the optimal detection range of this method (data not shown). Thus, a more sensitive barium-iodide staining technique [43] was selected to analyse HEK293T-CD63-eGFP EV samples.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Although PEG could be quantified in PEG-containing control samples, the PEG concentration within the final HEK293T-CD63-eGFP EV samples (clone B2 and C5 EVs were tested) was below the optimal detection range of this method (data not shown). Thus, a more sensitive barium-iodide staining technique [43] was selected to analyse HEK293T-CD63-eGFP EV samples.…”
Section: Resultsmentioning
confidence: 99%
“…After electrophoresis for 40 min at 200 V in MOPS-buffer (Thermo Fisher) gels were washed twice with distilled water. To visualise the PEG, gels were incubated for 10 min in freshly prepared 5% barium chloride (ROTH, Karlsruhe, Germany) and developed with 0.1 M iodide solution (ROTH, Karlsruhe, Germany) [43,44]. After the positive detection of the PEG signals, the solution was exchanged for distilled water.…”
Section: Methodsmentioning
confidence: 99%
“…12 Los geles fueron teñidos específicamente para proteínas con Coomassie brilliant blue (CBB) y para PEG con yodo. 13 La imágenes digitales de los geles fueron obenidas con un escaner ScanJet 4c/T (Hewlett Packard, Palo Alto, CA, USA) y analizadas con el software Molecular Analyst (Bio-Rad Laboratory, Hercules, CA, USA).…”
Section: Electroforesis En Geles De Poliacrilamida Y En Presencia De unclassified
“…Our results indicate that large proportional PEGylated protein could not be obtained by these acetonitrile is efficient to enhance the resolution of methods [8][9][10]. Sodium dodecyl sulfate-polyPEGylated proteins, while the total analysis time is acrylamide gel electrophoresis (SDS-PAGE) [11], reduced compared to the reported methods. high-performance liquid chromatography (HPLC)…”
Section: Introductionmentioning
confidence: 97%