Abstract: Following the significant improvement in their properties during the last decade, Distributed Fiber Optics sensing (DFOs) techniques are nowadays implemented for industrial use in the context of Structural Health Monitoring (SHM). While these techniques have formed an undeniable asset for the health monitoring of concrete structures, their performance should be validated for novel structural materials including Ultra High Performance Fiber Reinforced Cementitious composites (UHPFRC). In this study, a full scal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 46 publications
0
9
0
Order By: Relevance
“…It is important to mention that the SensoLux cable is the least sensitive to microcracks among the chosen FO cables, as it is characterized by low value of the strain lag parameter k [19]. The variation of strain measured with extensometers provoked by microcracking is clearly visible and in accordance with [14] as well as with [11,26,27]. While EXT1, 2 and 4 show good agreement with T2 fiber measurements, EXT3 shows higher strain.…”
Section: Strain Distribution In the Beammentioning
confidence: 66%
See 3 more Smart Citations
“…It is important to mention that the SensoLux cable is the least sensitive to microcracks among the chosen FO cables, as it is characterized by low value of the strain lag parameter k [19]. The variation of strain measured with extensometers provoked by microcracking is clearly visible and in accordance with [14] as well as with [11,26,27]. While EXT1, 2 and 4 show good agreement with T2 fiber measurements, EXT3 shows higher strain.…”
Section: Strain Distribution In the Beammentioning
confidence: 66%
“…The LunaÒ High-Definition Polyimide coating fiber of diameter Ø155 lm was glued to the flat surface of longitudinal rib from both sides of rebar before casting. Same type of fiber, as well as the SMF-28 ThorlabsÒ Ø900 lm fiber with elastomer tubing, were glued to the surface of UHPFRC in a previously prepared groove, as described in detail in [14]. The SensoLux cable Ø2000 lm was directly embedded in UHPFRC during casting.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Sawicki et al [ 68 ] proceeded to validate the performance of DOFS (integrated with DIC and extensometers) for the SHM of Ultra-High-Performance Fiber-Reinforced Cementitious composites (UHPFRC). In particular, a full-scale UHPFRC beam was instrumented with three lines of OFDR DOFS positioned inside 2 × 2 mm grooves present on each face of the beam (the fibers were glued in place with a bi-component epoxy adhesive).…”