2006
DOI: 10.1124/dmd.106.009241
|View full text |Cite
|
Sign up to set email alerts
|

Detection and Characterization of Metabolites in Biological Matrices Using Mass Defect Filtering of Liquid Chromatography/High Resolution Mass Spectrometry Data

Abstract: ABSTRACT:An improved mass defect filter (MDF) method employing both drug and core structure filter templates was applied to the processing of high resolution liquid chromatography/mass spectrometry (LC/ MS) data for the detection and structural characterization of oxidative metabolites with mass defects similar to or significantly different from those of the parent drugs. The effectiveness of this approach was investigated using nefazodone as a model compound, which is known to undergo multiple common and unco… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
186
1
1

Year Published

2007
2007
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 207 publications
(189 citation statements)
references
References 30 publications
1
186
1
1
Order By: Relevance
“…Recently, accompanying the enhanced resolution of mass spectrometry (MS), several algorithm-based methods, such as mass defect filtering techniques, have been developed in the drug metabolism field (Mortishire-Smith et al, 2005;Zhu et al, 2006). In essence, these metabolite searching methods use the numerical values of mass increase or decrease caused by known metabolic reactions or an artificial mass defect window as the screening filter to identify the metabolites formed by single or even multiple reactions.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, accompanying the enhanced resolution of mass spectrometry (MS), several algorithm-based methods, such as mass defect filtering techniques, have been developed in the drug metabolism field (Mortishire-Smith et al, 2005;Zhu et al, 2006). In essence, these metabolite searching methods use the numerical values of mass increase or decrease caused by known metabolic reactions or an artificial mass defect window as the screening filter to identify the metabolites formed by single or even multiple reactions.…”
Section: Introductionmentioning
confidence: 99%
“…is is especially true when signal doublet responses are low. 51) Setting acceptable tolerance for wanted ratios is still empirical, which results in the challenges while tracing one speci c ratio. 52) An additional statistical procedure to assist the conventional isotope-labeling method was reported by Lin et al in 2010.…”
Section: Methods Of Mass Spectrometry In Dis-covery Of Exposure Markermentioning
confidence: 99%
“…Various methods have been developed to perform objective searching/ ltering of accurate-mass-based LC-HRMS data to facilitate metabolite detection, such as isotope pattern lters (IPF), 42) mass defect ltering (MDF), 35,43) XCMS Online, 44) background subtraction, 45,46) and knowledgebased metabolic predictions. 47) A combination of di erent analytical technologies and data mining tools is needed to e ciently and thoroughly identify metabolites for discovering the biomarkers of exposure, toxic e ects, or diseases.…”
Section: Methods Of Mass Spectrometry In Dis-covery Of Exposure Markermentioning
confidence: 99%
See 1 more Smart Citation
“…The data were analyzed for molecules showing the mass defect of TCC (0.0220 6 0.05 Da). The range of 60.05 Da covers most metabolic reactions, but the loss of chlorine or addition of GSH causes a greater increase in mass defect (Zhang et al, 2003;Zhu et al, 2006). Therefore, other filters were used for the mass defects of 29-OH-TCC GSH adduct -0.0411 Da (Baumann et al, 2010) and potential bis-GSH adduct -0.1093 Da, as well as DHC (-0.0119) and its GSH and bis-GSH adducts -0.0801 Da and -0.1482 Da each in a range of 60.05 Da.…”
Section: Radiochemicalmentioning
confidence: 99%