Detailed Study of Furan Fatty Acids in Total Lipids and the Cholesteryl Ester Fraction of Fish Liver

Abstract: Furan fatty acids (F-acids) are valuable, bioactive minor components in lipids which are characterized by a furan moiety in the acyl chain. Here, we present a gas chromatography/mass spectrometry method operated in the selected ion monitoring mode (GC/MS-SIM) for the thorough determination of F-acid as methyl esters in fish. The method takes advantage of the molecular ion and two characteristic fragment ions and enables the unequivocal detection of >350 saturated, mono-and dienoic F-acids in four GC/MS-SIM run… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
29
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

6
1

Authors

Journals

citations
Cited by 23 publications
(33 citation statements)
references
References 27 publications
3
29
0
1
Order By: Relevance
“…5b). These three fragment ions can be used for the identification of triacylglycerols with 9M5 (similarly, triacylglycerols with other FuFA can be identified by characteristic low mass fragment ions [Wendlinger et al, ]). In the high mass range, triacylglycerols (with conventional fatty acids, no FuFA) do not form molecular ions but characteristic [M‐RCOO] + fragment ions (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…5b). These three fragment ions can be used for the identification of triacylglycerols with 9M5 (similarly, triacylglycerols with other FuFA can be identified by characteristic low mass fragment ions [Wendlinger et al, ]). In the high mass range, triacylglycerols (with conventional fatty acids, no FuFA) do not form molecular ions but characteristic [M‐RCOO] + fragment ions (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…FuFAs were identified by means of their mass spectra as reported elsewhere [15,41,42] Table 1). Similar abundance ratios of the GC/ MS-SIM ions as in 8F6-ME were requested for the assignment of other N-FuFAs (tolerated absolute deviation ± 6%, Table 1).…”
Section: Fufa Identification Quantification and Quality Controlmentioning
confidence: 99%
“…Measurements were performed using a 6890/5973 system operated under conditions described elsewhere, 31 except for the oven programme which was the same as for the GC/ECNI-MS. The measurements were performed in full scan mode (m/z 50 to 650).…”
Section: Gas Chromatography Coupled With Electron Ionization Mass Smentioning
confidence: 99%