2014
DOI: 10.1016/j.jfluchem.2014.01.002
|View full text |Cite
|
Sign up to set email alerts
|

Detailed copolymerization propagation kinetics of homogeneous phase VDF–HFP copolymerization in supercritical CO2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 10 publications
(25 citation statements)
references
References 39 publications
0
23
0
2
Order By: Relevance
“…k p ijk in Scheme refers to the addition of monomer k to a macroradical consisting of monomer i in the penultimate unit and monomer unit j as terminal unit at the chain end. The penultimate unit model has been applied to numerous copolymerization systems against data obtained by PLP–SEC, e.g., in refs . To describe the copolymerization behavior, six parameters are employed in addition to the homopropagation rate coefficients: r 11 = k p111 / k p112 , r 21 = k p211 / k p212 , s 1 = k p211 / k p111 , r 22 = k p222 / k p221 , r 12 = k p122 / k p121 , and s 2 = k p122 / k p222 .…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…k p ijk in Scheme refers to the addition of monomer k to a macroradical consisting of monomer i in the penultimate unit and monomer unit j as terminal unit at the chain end. The penultimate unit model has been applied to numerous copolymerization systems against data obtained by PLP–SEC, e.g., in refs . To describe the copolymerization behavior, six parameters are employed in addition to the homopropagation rate coefficients: r 11 = k p111 / k p112 , r 21 = k p211 / k p212 , s 1 = k p211 / k p111 , r 22 = k p222 / k p221 , r 12 = k p122 / k p121 , and s 2 = k p122 / k p222 .…”
Section: Introductionmentioning
confidence: 99%
“…Previously, it was shown that the combination of pulsed laser initiated polymerization and subsequent analysis of the resulting polymer by size‐exclusion chromatography (PLP–SEC method) allows for the determination of k p copo . After establishing appropriate reaction conditions, k p copo is derived from Equation L = knormalpcopocnormalMtwith c M being the monomer concentration, t the time between two subsequent laser pulses, and L the number of propagation steps derived from the point of inflection of the molar mass distribution (MMD).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Die Kalibrierung erfolgt mit Polystyrol‐Standards (PSS). Absolute Molmassen werden basierend auf dem Prinzip der universellen Kalibrierung berechnet , . Die folgenden Mark‐Houwink‐Parameter werden genutzt: a (PS) = 0,69; K (PS) = 0,013 mL g −1 ; a (PVDF) = 0,68 und K (PVDF) = 0,018 mL g −1 .…”
Section: Experimentellesunclassified
“…Es stellt sich ein Gleichgewicht zwischen wachsenden und schlafenden Polymerketten ein [14]. [17,18]. Die folgenden Mark-Houwink-Parameter werden genutzt: a(PS) = 0,69; K(PS) = 0,013 mL g -1 ; a(PVDF) = 0,68 und K(PVDF) = 0,018 mL g -1 .…”
Section: Introductionunclassified