2010
DOI: 10.1039/b925257f
|View full text |Cite
|
Sign up to set email alerts
|

Desorption electrospray ionization and other ambient ionization methods: current progress and preview

Abstract: Mass spectrometry allows rapid chemical analysis of untreated samples in the ambient environment. This is a result of recent rapid progress in ambient ionization techniques. The most widely studied of these new methods, desorption electrospray ionization (DESI), uses fast-moving solvent droplets to extract analytes from surfaces and propel the resulting secondary microdroplets towards the mass analyzer. This review of DESI and other ambient methods centers on the accompanying chemical processes. Manipulation o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
305
0
1

Year Published

2012
2012
2016
2016

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 346 publications
(308 citation statements)
references
References 76 publications
1
305
0
1
Order By: Relevance
“…Ambient ionization [6][7][8][9][10][11][12][13][14] is a relatively recent approach to MS analysis which avoids chromatography and is characterized by the absence of any requirement for sample preparation. Paper spray ionization [15][16][17][18][19][20] is a particularly simple ambient ionization technique which can be employed to study reactions and identify intermediates as well as to measure trace constituents of complex mixtures. Like other spray ionization methods, paper spray is least successful for non-polar or weakly polar compounds.…”
Section: Introductionmentioning
confidence: 99%
“…Ambient ionization [6][7][8][9][10][11][12][13][14] is a relatively recent approach to MS analysis which avoids chromatography and is characterized by the absence of any requirement for sample preparation. Paper spray ionization [15][16][17][18][19][20] is a particularly simple ambient ionization technique which can be employed to study reactions and identify intermediates as well as to measure trace constituents of complex mixtures. Like other spray ionization methods, paper spray is least successful for non-polar or weakly polar compounds.…”
Section: Introductionmentioning
confidence: 99%
“…1, 5 of CTH in bulk reaction mixtures (reaction time of a few minutes) (15). Ambient ionization methods (24)(25)(26) such as desorption electrospray ionization (DESI) (27)(28)(29) provide a simpler approach to intercepting reactive species without prior sample preparation (30)(31)(32)(33)(34)(35). We recently demonstrated that DESI can intercept CTH intermediates in solution on the millisecond time scale (36).…”
mentioning
confidence: 99%
“…[11][12][13][14] Most ambient MS methods were primarily utilized for analysing metabolites and lipids. [15][16][17][18] Protein analysis from dried biological samples such as blood, cell cultures, and tissues was demonstrated by electrospray assisted laser desorption ionization (ELDI) MS. 19 In extracts and crude samples, desorption electrospray ionization (DESI) provided peptide and protein analysis including top down sequencing.…”
Section: 10mentioning
confidence: 99%