2018 2nd International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT) 2018
DOI: 10.1109/ismsit.2018.8567049
|View full text |Cite
|
Sign up to set email alerts
|

Desing and Test of an Incubator Analyzer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 1 publication
0
7
0
Order By: Relevance
“…To maintain the accuracy of its parameters, the baby incubator requires calibration. The equipment used for calibrating or assessing the condition of the baby incubator room is known as the Incubator Analyzer [10]. The Incubator Analyzer is capable of measuring room and mattress temperature (°C), air humidity (%RH), airflow, and noise level (dB) [9].…”
Section: Introductionmentioning
confidence: 99%
“…To maintain the accuracy of its parameters, the baby incubator requires calibration. The equipment used for calibrating or assessing the condition of the baby incubator room is known as the Incubator Analyzer [10]. The Incubator Analyzer is capable of measuring room and mattress temperature (°C), air humidity (%RH), airflow, and noise level (dB) [9].…”
Section: Introductionmentioning
confidence: 99%
“…The baby incubator calibration device, the incubator analyzer, can help determine whether a baby incubator is eligible or not [3]. To ensure the accuracy of medical devices, periodic tests and controls need to be carried out, aimed at reducing the risk or preventing inaccurate or inaccurate measurements [4]. If the noise and airflow parameters of the baby incubator are made inadequate or inaccurate measurements, it can threaten the baby's safety.…”
Section: Introductionmentioning
confidence: 99%
“…Emre Ozdemđ, et al [4] once analyzed the "Reliability Assessments of Infant Incubators and the Analyzer" states that if a baby incubator exceeds the normal limits agreed upon, it will harm the baby, for example, if the airflow exceeds the normal limit will Asphyxia occurs in infants, and if the noise exceeds the normal limit there will be dizziness, increased blood pressure, and decreased fluid in the baby's brain [3] In 2018, G.Gnancy Subha and M.Fazilath made an incubator analyzer using sensors to detect the presence of toxic gas in baby incubators. The study stated that the parameters of temperature, humidity, noise, and airflow in the baby incubator must be at the limit that refers to ANSI / AAMI.…”
Section: Introductionmentioning
confidence: 99%
“…The incubator functions to keep the baby's body warm and moist. The working principle of the baby incubator is to regulate and stabilize the temperature in the incubator room to match the temperature required by premature babies [2].…”
Section: Introductionmentioning
confidence: 99%