Designing HVDC GIS/GIL spacer to suppress charge accumulation

Abstract: To suppress the charge accumulation on the spacer surface in direct current (DC) gas insulated transmission line (GIL) is an important and emergent issue for the development of a clean, safe and economic smart grid. A design method of the DC spacer is proposed, and a spacer prototype is prepared and evaluated both by simulation and type test. The DC withstand voltage test and polarity reversal test are performed using the new DC spacer compared with a commercialised 220 kV AC spacer. The simulation results ind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 19 publications
(20 reference statements)
0
5
0
Order By: Relevance
“…The concentrations of positive and negative charges are closely related to its microscopic behaviour, including the generation, recombination, migration, and diffusion process [22]. The variation of charged particle concentration can be characterised by the following Equation (6).…”
Section: The Mathematics-physics Equations Of Surface Charge Accumula...mentioning
confidence: 99%
See 1 more Smart Citation
“…The concentrations of positive and negative charges are closely related to its microscopic behaviour, including the generation, recombination, migration, and diffusion process [22]. The variation of charged particle concentration can be characterised by the following Equation (6).…”
Section: The Mathematics-physics Equations Of Surface Charge Accumula...mentioning
confidence: 99%
“…In recent years, gas-solid interface charge regulation becomes continuously hot research spot [6,7]. Numerous surface modification methods are proposed to improve surface charge and electric field distribution [8,9].…”
Section: Introductionmentioning
confidence: 99%
“…To satisfy the increasing voltage level and complex operating conditions, higher requirements are put forward for the reliability and stability of gas insulated transmission lines (GILs), especially in high voltage direct current transmission systems [1][2][3][4][5]. Among the types of GIL accidents, insulator failure could bring irreversible damage, which is usually * Author to whom any correspondence should be addressed.…”
Section: Introductionmentioning
confidence: 99%
“…The current research on the structure of the DC basin-type insulator is still very scarce, and most of them are simple exploratory or tentative studies. Liang et al optimised the shape of the insulator by adjusting the tilt angle to change the surface normal electric field [18]. Instead of employing any optimisation algorithm, Zebouchi et al performed a parametric sweep of selected geometric control parameters to obtain the optimal insulator shape [19].…”
Section: Introductionmentioning
confidence: 99%
“…Liang et al. optimised the shape of the insulator by adjusting the tilt angle to change the surface normal electric field [18]. Instead of employing any optimisation algorithm, Zebouchi et al.…”
Section: Introductionmentioning
confidence: 99%