2006
DOI: 10.1002/chin.200615176
|View full text |Cite
|
Sign up to set email alerts
|

Design, Synthesis and Evaluation of Near‐Infrared Fluorescent pH Indicators in a Physiologically Relevant Range.

Abstract: ChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 200 leading journals. To access a ChemInform Abstract, please click on HTML or PDF.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
20
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(20 citation statements)
references
References 1 publication
0
20
0
Order By: Relevance
“…Difference of fluorescent intensity between t n and t n-1 I n is represented by equation 8. (10) In this compensation method, initial fluorescent intensity I 0 , Fluorescent intensities at t n , t n-1 I n , I n-1 .are required for compensation of photo-bleaching. Therefore, this method can be applied to real time compensation since calculation cost is quite low.…”
Section: Compensation Of Photo-bleaching Using Difference Compensamentioning
confidence: 99%
See 1 more Smart Citation
“…Difference of fluorescent intensity between t n and t n-1 I n is represented by equation 8. (10) In this compensation method, initial fluorescent intensity I 0 , Fluorescent intensities at t n , t n-1 I n , I n-1 .are required for compensation of photo-bleaching. Therefore, this method can be applied to real time compensation since calculation cost is quite low.…”
Section: Compensation Of Photo-bleaching Using Difference Compensamentioning
confidence: 99%
“…This method uses the environmental dependency of quantum yield of fluorescent indicators. By using this method, various parameters, such as temperature, pH, oxygen, calcium ion, are measured [9,10]. However, fluorescent intensity from the indicator decreases by photochemical destruction of the indicator during measurement [11].…”
Section: Introductionmentioning
confidence: 99%
“…Advances in the digital imaging technology, have now permitted the extension of fiber-optico fluorosensor techniques to two dimensions with high spatial resolution [8][9][10][11][12]. However, fluorescent methods have major problems with absorption with some molecules, quenching and photo-degradation.…”
Section: Introductionmentioning
confidence: 99%
“…Conventionally, fluorescence observation was the major approach for environmental measurements (Shinohara et al 2004;Nishimura et al 2005;Zhang and Achilefu 2005;Klauke et al 2006). On the pH measurement, a pH-sensing microscope has been developed (Nakao et al 1995).…”
Section: Introductionmentioning
confidence: 99%