2008
DOI: 10.1109/tpwrd.2007.908789
|View full text |Cite
|
Sign up to set email alerts
|

Design, Simulation, and Analog Circuit Implementation of a Three-Phase Shunt Active Filter Using the ${\rm I}\cos\Phi$ Algorithm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
34
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 110 publications
(34 citation statements)
references
References 14 publications
0
34
0
Order By: Relevance
“…The outer voltage loop regulates the square of v c to a reference signal v 2 ref with a simple PI compensator [33], [34]. Using the square of v c instead of v c , the design of this loop is simpler, as discussed in Section III.…”
Section: A Indirect Current-control Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The outer voltage loop regulates the square of v c to a reference signal v 2 ref with a simple PI compensator [33], [34]. Using the square of v c instead of v c , the design of this loop is simpler, as discussed in Section III.…”
Section: A Indirect Current-control Methodsmentioning
confidence: 99%
“…From the Tellegen theorem, the energy balance of the APF system, assuming no losses and negligible energy stored in the inductor, can be expressed as [33], [34] d dt…”
Section: Appendix Small-signal Model Of the Outer Voltage Loopmentioning
confidence: 99%
“…On the other hand, when the load is unbalanced, there will be current in neutral wire. the total power of zero sequence component will be obtained from (14). To decrease the neutral current, the total zero sequence power must be supplied by shunt APF and this index must also be injected into main axis.…”
Section: Reference Current Signal Generation Of the Shunt Apfmentioning
confidence: 99%
“…In the past few years, several control strategies have been presented in literature for determining the voltage and current reference signals. Some of the most common strategies include p-q-r theory [10], improved single-phase p-q theory [11], synchronous reference frame (SRF) theory [12], symmetric component transformation [13], Icos theory [14,15] and some other innovative control methods [16,17]. In [18], the one-cycle control approach (without calculating the reference) is used for controlling a three-phase four-wire UPQC.…”
Section: Introductionmentioning
confidence: 99%
“…To extract the fundamental source voltages as reference signals for series APF, a zero-crossing detector and sample-and-hold circuits are used. The control of shunt APF is based on I CosΦ theory [20,21].…”
Section: Introductionmentioning
confidence: 99%