2002
DOI: 10.1049/ip-smt:20020647
|View full text |Cite
|
Sign up to set email alerts
|

Design of solid broadband human tissue simulant materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(13 citation statements)
references
References 10 publications
0
12
0
Order By: Relevance
“…Moreover melon pulp has higher dielectric constant than its skin (Nelson et al, 2008). The same differences can be identified as regards grey matter and muscle in comparison to human skin (Young et al, 2002). However, electric properties of materials are complex and vary depending on frequency of the applied field, temperature, and other parameters.…”
Section: Methodsmentioning
confidence: 84%
“…Moreover melon pulp has higher dielectric constant than its skin (Nelson et al, 2008). The same differences can be identified as regards grey matter and muscle in comparison to human skin (Young et al, 2002). However, electric properties of materials are complex and vary depending on frequency of the applied field, temperature, and other parameters.…”
Section: Methodsmentioning
confidence: 84%
“…The accuracy of phantoms with respect to real tissues is often specified by the root-mean-square error (RMSE), but also by the mean squared error (MSE) and the relative error. From Table II, one can observe that many of them have large deviations [40], [96], [98], [101], [103], [104]. Others do not even conform to tissue values, but such phantoms are created so that the differences between their values are equivalent to those of the tissues of interest [92], [100].…”
Section: B a Experimental Tissue-equivalent Phantomsmentioning
confidence: 99%
“…Muscle phantoms, in particular, are given in four different works in Table II, with a high contrast between their errors. Both [40] and [98] exhibit a high deviation from the reference values, whereas [101] just provides a first-order match. The muscle phantom from [39], [41] has the highest accuracy, with a really low RMSE.…”
Section: B a Experimental Tissue-equivalent Phantomsmentioning
confidence: 99%
“…Regarding mechanical properties, there are liquid [5,6], solid [7][8][9][10] and gel based phantom materials [11][12][13][14][15][16]. When liquid mixtures are used, always appropriate containers are needed that hold the liquid.…”
Section: Introductionmentioning
confidence: 99%