2014 9th IEEE Conference on Industrial Electronics and Applications 2014
DOI: 10.1109/iciea.2014.6931233
|View full text |Cite
|
Sign up to set email alerts
|

Design of passive power filters for a three-phase semi-controlled rectifier with typical loads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 5 publications
0
11
0
Order By: Relevance
“…Equations (3), (4), (6), (8) and (9) are used to establish filter output current expression given in (16). Assuming that grid voltage total distortion harmonics is sufficiently low, high frequency grid voltage component V gi HF (s) can be neglected.…”
Section: • Mode 3: Grid Supporting Modementioning
confidence: 99%
See 3 more Smart Citations
“…Equations (3), (4), (6), (8) and (9) are used to establish filter output current expression given in (16). Assuming that grid voltage total distortion harmonics is sufficiently low, high frequency grid voltage component V gi HF (s) can be neglected.…”
Section: • Mode 3: Grid Supporting Modementioning
confidence: 99%
“…Assuming that grid voltage total distortion harmonics is sufficiently low, high frequency grid voltage component V gi HF (s) can be neglected. High frequency component of filter current is than deduced from (16) and expressed in (17). This current I fi HF is resonant at the frequency is given by (18) The resonance frequency depends on L g grid inductance which is related to grid conditions: weak or strong grid.…”
Section: • Mode 3: Grid Supporting Modementioning
confidence: 99%
See 2 more Smart Citations
“…Besides the advantage of being simple and cheap and highly reliable, there is the disadvantage of the need for a new design for every new case, the filters should be tuned to a specific harmonic to act correctly and may lead to over voltage during low power demand. It is worth noting that these filters are used nowadays in some application beside disadvantages because of being simple design and coseffectiveResearch in the application and novel methods to design of this filter is still going on in three phase and single phase power systems, although most of them are some hybrid applications of filters to reduce the costs and increase the reliability of the system [33,[47][48][49][50][51][52][53][54][55][56].…”
Section: Passive Power Filtersmentioning
confidence: 99%