2017
DOI: 10.1140/epjd/e2017-70825-3
|View full text |Cite
|
Sign up to set email alerts
|

Design of ITER divertor VUV spectrometer and prototype test at KSTAR tokamak

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…In KSTAR, several imaging diagnostics with tomographic reconstruction algorithms have been developed for impurity transport study [8][9][10][11], including the tungsten powder injection experiment. However, both the vacuum (VUV) and extreme ultraviolet (EUV) spectrometers [10,12] on KSTAR and the one planned for ITER [13], which have a capability of resolving the spatial distribution of line emissions, suffer from a limited viewing angle due to the narrow allocated space, which makes it difficult to accurately reconstruct the local emissivity profile of each line radiation from the chordintegrated data. The ITER VUV spectrometers are expected to employ 5 channels having different fields of view (FoVs) with different wavelengths [12][13][14].…”
Section: Local Profiles Of Line Emission Of Impurity Ions In Rotating...mentioning
confidence: 99%
See 3 more Smart Citations
“…In KSTAR, several imaging diagnostics with tomographic reconstruction algorithms have been developed for impurity transport study [8][9][10][11], including the tungsten powder injection experiment. However, both the vacuum (VUV) and extreme ultraviolet (EUV) spectrometers [10,12] on KSTAR and the one planned for ITER [13], which have a capability of resolving the spatial distribution of line emissions, suffer from a limited viewing angle due to the narrow allocated space, which makes it difficult to accurately reconstruct the local emissivity profile of each line radiation from the chordintegrated data. The ITER VUV spectrometers are expected to employ 5 channels having different fields of view (FoVs) with different wavelengths [12][13][14].…”
Section: Local Profiles Of Line Emission Of Impurity Ions In Rotating...mentioning
confidence: 99%
“…However, both the vacuum (VUV) and extreme ultraviolet (EUV) spectrometers [10,12] on KSTAR and the one planned for ITER [13], which have a capability of resolving the spatial distribution of line emissions, suffer from a limited viewing angle due to the narrow allocated space, which makes it difficult to accurately reconstruct the local emissivity profile of each line radiation from the chordintegrated data. The ITER VUV spectrometers are expected to employ 5 channels having different fields of view (FoVs) with different wavelengths [12][13][14]. Therefore, inadequate lines of sight (LoSs) may lead to the inaccurate local profiles by using the conventional tomographic methods.…”
Section: Local Profiles Of Line Emission Of Impurity Ions In Rotating...mentioning
confidence: 99%
See 2 more Smart Citations
“…Murakami et al [16] presented a detailed collisional-radiative model for W 27+ , including a comprehensive set of excitation and recombination processes for plasma diagnostics. Further to this work, Seon et al [17] discussed progress on the design and development of an ITER diverter VUV spectrometer, particularly attuned to representative tungsten emission lines resulting from the tungsten diverter material. Its usefulness as a plasma diagnostic follows directly from the experimental and theoretical information on radiative transition probabilities.…”
Section: Summary Of Contributionsmentioning
confidence: 99%