2013
DOI: 10.1016/j.talanta.2013.06.025
|View full text |Cite
|
Sign up to set email alerts
|

Design of interpenetrated network MWCNT/poly(1,5-DAN) on interdigital electrode: Toward NO2 gas sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 19 publications
0
6
0
Order By: Relevance
“…Nguyen et al 178 prepared an interpenetrated network of MWCNT-poly(1,5-DAN) on IDE for NO 2 sensing (Figure 20). The MWCNT dispersed in Nafion was drop-coated onto Pt-IDE, followed by electro-polymerization of poly(1,5-DAN).…”
Section: Chemical Reviewsmentioning
confidence: 99%
“…Nguyen et al 178 prepared an interpenetrated network of MWCNT-poly(1,5-DAN) on IDE for NO 2 sensing (Figure 20). The MWCNT dispersed in Nafion was drop-coated onto Pt-IDE, followed by electro-polymerization of poly(1,5-DAN).…”
Section: Chemical Reviewsmentioning
confidence: 99%
“…Figure 11 presents the corresponding SWVs and calibration curve. The same group also demonstrated a new approach to fabricate CPs/CNTs hybrid using a mixture of Nafion ® (DuPont, Wilmington, DE, USA) and MWCNTs first deposited on the electrode surface, followed by 1,5-DAN electropolymerization [ 100 , 101 ], for determination of Cd 2+ and Pb 2+ by SWASV over the range 4–150 µg·L − 1 and LoDs of 3.2 and 2.1 µg·L − 1 for Cd 2+ and Pb 2+ , respectively.…”
Section: Conducting Polymer-modified Electrodesmentioning
confidence: 99%
“…As shown, the most intense peak current signaling Pb 2+ was obtained at the poly(1,5‐DAN)/RGO/Pt electrode. Comparison of these CVs allowed to ascribe the enhancement of peak current between curve b and curve d to RGO, namely to the high specific area and high electrical conductivity brought by RGO within the poly(1,5‐DAN) layer, while the polymer was able to chelate Pb 2+ via its free amino groups .…”
Section: Resultsmentioning
confidence: 99%
“…However, poly(DAN) suffers from low electrical conductivity and high compactness that could limit the diffusion of the target analytes and therefore could diminish the sensor performances. To further improve these performances, poly(1,5‐DAN) was used in composites with various materials like metal nanoparticles or carbon nanotubes (CNTs) . CNTs were also used after functionalization with ionophores, for example 2‐(5‐bromo‐2‐pyridylazo)‐5‐diethylaminophenol .…”
Section: Introductionmentioning
confidence: 99%