1980
DOI: 10.1016/0021-9681(80)90044-2
|View full text |Cite
|
Sign up to set email alerts
|

Design of human atherosclerosis studies by serial angiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
6
0

Year Published

1985
1985
1993
1993

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(6 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…Branch points on the femoral angiogram were marked and used for registration, duplicating the procedure used in pilot studies of replication. 19 Film digitization was carried out with a Joyce Loebl SCANDIG 3 rotating drum digitizer. In this instrument, a tungsten halogen lamp is mounted opposite a photodiode on an optical carriage that moves along the axis of the transparent rotating drum.…”
Section: Angiographic Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Branch points on the femoral angiogram were marked and used for registration, duplicating the procedure used in pilot studies of replication. 19 Film digitization was carried out with a Joyce Loebl SCANDIG 3 rotating drum digitizer. In this instrument, a tungsten halogen lamp is mounted opposite a photodiode on an optical carriage that moves along the axis of the transparent rotating drum.…”
Section: Angiographic Analysismentioning
confidence: 99%
“…*Analysis using the modeling approach due to Rossner22 against a one-sided alternative. tCEA range: quartile 1 (11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27), quartile 2 (28-35), quartile 3 (36-48), quartile 4 (49-180). groups (Figure 1).…”
Section: Per-patient Analysismentioning
confidence: 99%
“…Several such quantitative methods have been investigated (5,6,12) to improve reproducibility. Analysis of computerized images with image processing of the femoral angiograms has been in use since 1986 in the Probucol Quantitative Regression Swedish Trial (PQRST) (15).…”
mentioning
confidence: 99%
“…From this array estimates of the arterial diameter, cross-sectional area and edge irregularity can be computed. A few clinical studies on digitized femoral arteriograms have been published (3,4,9), but most efforts in this field have been devoted to coronary cineangiograms (5,14,17,20,21). In order to detect changes in femoral artery atheroma volume over time, we have developed a method for estimating the femoral artery lumen volume.…”
mentioning
confidence: 99%