2019
DOI: 10.1016/j.jece.2018.102849
|View full text |Cite
|
Sign up to set email alerts
|

Design of high-performance adsorption cross-linked organic functional polymers towards tricyclic antidepressants using computational simulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 46 publications
2
8
0
Order By: Relevance
“…As observed in Figure S1, the highest anodic current was observed at pH 7.0. Under this pH value, the E2 molecule (pKa 10.7) is in its molecular form [51], while the pKa for the carboxylic group present in poly(methacrylic acid) acid grafted on the MWCNT surface might reach a value of 7.3 [52]. Therefore, it seems that the interaction of the E2 molecule with the nanocomposite may take place by hydrogen bonds with the carboxylic group and by stack interactions with the MWCNT.…”
Section: Influence Of Ph Type and Concentration Of The Supporting Ele...mentioning
confidence: 98%
“…As observed in Figure S1, the highest anodic current was observed at pH 7.0. Under this pH value, the E2 molecule (pKa 10.7) is in its molecular form [51], while the pKa for the carboxylic group present in poly(methacrylic acid) acid grafted on the MWCNT surface might reach a value of 7.3 [52]. Therefore, it seems that the interaction of the E2 molecule with the nanocomposite may take place by hydrogen bonds with the carboxylic group and by stack interactions with the MWCNT.…”
Section: Influence Of Ph Type and Concentration Of The Supporting Ele...mentioning
confidence: 98%
“…Synthesis of the polymers was based on our previous study as well as the choice of functional monomers by computation simulation. 30 For chromatographic analysis, a Kinetex core–shell C18 column from Phenomenex® (Torrance, California, USA), with dimensions of 250 mm × 4.6 mm and a 5 μm particle size, was used. Other columns, a Kinetex C18 column from Phenomenex® (Torrance, California, USA), with dimensions of 250 mm × 4.5 mm and a 5 μm particle size, and a Luna Phenomenex C8 column, with dimensions of 250 mm × 4.6 mm and a 5 μm particle size, were also evaluated.…”
Section: Methodsmentioning
confidence: 99%
“…These equilibrium times were determined from our recent publication. 30 Subsequently, the obtained suspensions were centrifuged at 3000 rpm for 5 minutes. The supernatant was filtered through a 0.45 μm Nylon® syringe filter and injected into the chromatographic system to determine the remaining TCAs.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations