2018
DOI: 10.12928/telkomnika.v16i4.7127
|View full text |Cite
|
Sign up to set email alerts
|

Design of Electronic Nose System Using Gas Chromatography Principle and Surface Acoustic Wave Sensor

Abstract: Most gases are odorless, colorless and also hazard to be sensed by the human olfactory system. Hence, an electronic nose system is required for the gas classification process. This study presents the design of electronic nose system using a combination of Gas Chromatography Column and a Surface Acoustic Wave (SAW). The Gas Chromatography Column is a technique based on the compound partition at a certain temperature. Whereas, the SAW sensor works based on the resonant frequency change. In this study, gas sample… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
8
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 26 publications
1
8
0
1
Order By: Relevance
“…QCM sensor contains a piezoelectric material which is quartz and sandwiched between two electrodes. When a voltage which is electrical signal that consist of electron is applied to the electrode, the piezoelectric effect will convert the electrical signal into mechanical vibration in terms of acoustic wave [22,23]. Then, the mechanical vibration will be converted back to the electrical signal.…”
Section: Design Conceptmentioning
confidence: 99%
“…QCM sensor contains a piezoelectric material which is quartz and sandwiched between two electrodes. When a voltage which is electrical signal that consist of electron is applied to the electrode, the piezoelectric effect will convert the electrical signal into mechanical vibration in terms of acoustic wave [22,23]. Then, the mechanical vibration will be converted back to the electrical signal.…”
Section: Design Conceptmentioning
confidence: 99%
“…(3,4) Gas chromatograph is one of the best techniques used for the analysis of organic volatile compounds employing various detectors. In order to make the fast analysis researcher optimized the various parameters for development of fast gas chromatography (5)(6)(7)(8)(9) . The sensitivity and resolution are the key parameter of any gas sensor system.…”
Section: Introductionmentioning
confidence: 99%
“…The Flame ionization (FID), Thermal conductivity (TCD), photo-ionization (PID) etc., are non-selective detectors whereas nitrogen phosphorous (NPD), electron capture (ECD), or mass (MS) are selective detectors. The property of few detectors shown in the Table 1 (3)(4)(5)(6)10,11) . SAW detector used as Non-selective GC detector shows the linear response towards the mass change over the surface of the detector (6) .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…TA adalah kelas A yang diklasifikasikan dengan benar, TB adalah kelas B yang diklasifikasikan dengan benar, TC adalah kelas C yang diklasifikasikan dengan benar. FA1 adalah kelas B yang diklasifikasikan ke dalam kelas A, FA2 adalah kelas C yang diklasifikasikan ke dalam kelas A. FB1 adalah kelas A yang diklasifikasikan ke dalam kelas B, FB2 adalah kelas C yang diklasifikasikan ke dalam kelas B. FC1 adalah kelas A yang diklasifikasikan ke dalam kelas C, FC2 adalah kelas B yang diklasifikasikan ke dalam kelas C[15]. dengan confusion matrix pada Tabel 2, maka TN untuk kelas A yaitu TB+FB2+FC2+TC, FP untuk kelas A yaitu FA1+FA2.…”
unclassified