Economical Bridge Solutions Based on Innovative Composite Dowels and Integrated Abutments 2014
DOI: 10.1007/978-3-658-06417-4_4
|View full text |Cite
|
Sign up to set email alerts
|

Design of composite dowels as shear connectors according to the German technical approval

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…Compared with the headed stud, composite dowel shear connection possesses better shear bearing capacity and superior deformation capacity. For ease of the subsequent illustration, the notations of composite dowels are used and shown in the Figure 15 (Markus et al, 2014). When thickness of the steel dowels is thinner or the strength is lower, it usually leads to shear failure of the steel dowels.…”
Section: Shear Bearing Capacity Of Composite Dowel Connectormentioning
confidence: 99%
See 2 more Smart Citations
“…Compared with the headed stud, composite dowel shear connection possesses better shear bearing capacity and superior deformation capacity. For ease of the subsequent illustration, the notations of composite dowels are used and shown in the Figure 15 (Markus et al, 2014). When thickness of the steel dowels is thinner or the strength is lower, it usually leads to shear failure of the steel dowels.…”
Section: Shear Bearing Capacity Of Composite Dowel Connectormentioning
confidence: 99%
“…The failure mode is generally controlled by the combination of bending moment and shear force. At present, the shear failure mechanism of steel dowels is based on the Mises stress of the critical section, and the design formula can be shown in formula (1) by using the specific geometrical parameters for the CL and PZ shape (Markus et al, 2014).…”
Section: Shear Bearing Capacity Of Composite Dowel Connectormentioning
confidence: 99%
See 1 more Smart Citation
“…Continuous shear connectors evolved from the perfobond strip [10], through open concrete dowels [11], [12] and to the composite dowels used nowadays [7]. Formal technical approval has been established in Germany [25], implementing design procedures established during the PreCo-Beam project and collected into design guidance during the Preco+ dissemination project [27]. Technical approval Z-26.4-56 [34] covers two shear connector shapes: PZ and MCL [5].…”
Section: Introductionmentioning
confidence: 99%
“…Currently, a distinction is made between composite dowels with either open (e.g. puzzle or clothoid strips ) or closed (e.g. Perfobond strips ) recesses.…”
Section: Introduction and Definition Of The Problemmentioning
confidence: 99%