2015
DOI: 10.1016/j.ijhm.2015.01.005
|View full text |Cite
|
Sign up to set email alerts
|

Design of an ice thermal energy storage system for a building of hospitality operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 23 publications
0
7
0
Order By: Relevance
“…Other simplified methods are available including the radiant time-series (RTS), the transfer function (TFM), the total equivalent temperature differential with time averaging (TETD/TA) and the cooling load temperature difference with cooling load factors (CLTD/CLF) methods. Previous research assessed the use of ITES estimating the building cooling load profile of commercial buildings with the CLTD/CLF method (Rismanchi et al, 2012), the TFM method (Wu & Yao-Hsu, 2015) and, simulation tools such as TRNSYS (Rismanchi et al, 2013) and Energy Plus (Sehar et al, 2012;Sehar et al, 2016;Yin et al, 2015).…”
Section: Commercial Buildings Cooling Load Profilesmentioning
confidence: 99%
See 1 more Smart Citation
“…Other simplified methods are available including the radiant time-series (RTS), the transfer function (TFM), the total equivalent temperature differential with time averaging (TETD/TA) and the cooling load temperature difference with cooling load factors (CLTD/CLF) methods. Previous research assessed the use of ITES estimating the building cooling load profile of commercial buildings with the CLTD/CLF method (Rismanchi et al, 2012), the TFM method (Wu & Yao-Hsu, 2015) and, simulation tools such as TRNSYS (Rismanchi et al, 2013) and Energy Plus (Sehar et al, 2012;Sehar et al, 2016;Yin et al, 2015).…”
Section: Commercial Buildings Cooling Load Profilesmentioning
confidence: 99%
“…Yin et al (2015) simulated ITES in office and retail buildings in California to assess its cost-effectiveness and demand response (DR) capabilities, and concluded that ITES can provide a reliable and fast load shed without interruption in the buildings occupants' comfort. Wu & Yao-Hsu (2015) concluded that the main driver for the uptake of ITES technology is economic. Sehar et al (2016) simulates a medium-sized office building with integrated solar PV, DR and ITES.…”
Section: Introductionmentioning
confidence: 99%
“…Sehar et al researched the effect of ITES for office buildings on electrical energy consumption. Wu and Tsai studied the design of an ITES system for a building of hospitality operation. They found that ITES system could decrease chiller capacity and cooling costs.…”
Section: Introductionmentioning
confidence: 99%
“…They found that modified electricity tariff may increase the economic benefit from the ITES system by 25%. Wu et al researched ITES system usage in the seven‐story commercial building in Tapei, Taiwan. They determined that if the AC systems were not operated at peak hours with partial storage, they would save 45 000 USD per year.…”
Section: Introductionmentioning
confidence: 99%