2012
DOI: 10.1063/1.3698297
|View full text |Cite
|
Sign up to set email alerts
|

Design of a vector magnet for the measurements of anisotropic magnetoresistance and rotational magneto-optic Kerr effect

Abstract: A vector magnet is designed and assembled with two electromagnets to produce a rotational magnetic field in any direction within a plane. This design allows a rotation of the magnetic field without a mechanical rotation of the magnets. The fast speed of the field rotation (~10 s for a complete 360° rotation) and the stability against mechanical vibration easily overcome the slow drifting effect in anisotropic magnetoresistance (AMR) and rotational magneto-optic Kerr effect (ROTMOKE) measurements. As an example… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(24 citation statements)
references
References 26 publications
0
24
0
Order By: Relevance
“…Therefore, the metallic Fe single crystal film gown on iron silicide buffer layer and Si(111) surface provides an ideal system to perform AMR measurements. In the case of Fe single-crystalline system, the AMR can be expressed as20212223242526: where φ M is the angle between the Fe magnetization M Fe and the current flow I , and is the resistance at φ M = 0° and φ M = 90°, respectively.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Therefore, the metallic Fe single crystal film gown on iron silicide buffer layer and Si(111) surface provides an ideal system to perform AMR measurements. In the case of Fe single-crystalline system, the AMR can be expressed as20212223242526: where φ M is the angle between the Fe magnetization M Fe and the current flow I , and is the resistance at φ M = 0° and φ M = 90°, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…On the other hand, the AMR results demonstrate that the symmetry of magnetocrystalline anisotropy energy changes from the six-fold to a superposition of six-fold, four-fold and a weakly uniaxial contribution due to the tiny misorientation from Fe(111) plane. Although the use of AMR to measure the magnetic anisotropy was introduced long time ago20212223242526, to our knowledge, a precise determination of various magnetic anisotropy constants of Fe(111) film on Si(111)-7 × 7 surface with so small miscut angle was not reported in literature. The fitted value of the first-order magnetocrystalline anisotropy K 1 is significantly influenced by the tiny variation of miscut angles β .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…After the MOKE hysteresis loop measurement, the sample was taken out of the UHV chamber and measured using a table top rotation MOKE (ROTMOKE) setup. A detailed description of our ROTMOKE setup was reported previously38. All MOKE and ROTMOKE measurements were performed at room temperature.…”
Section: Methodsmentioning
confidence: 99%
“…Magnetic hysteresis loop measurements were carried out using the longitudinal MOKE. 44 X-ray spectroscopy measurements were carried out at beamline 4.0.2 of the Advanced Light Source at Lawrence Berkeley National Laboratory. The measurements were performed in totalelectron-yield geometry.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%