2021
DOI: 10.1007/s00339-020-04261-3
|View full text |Cite
|
Sign up to set email alerts
|

Design of a Topas-based ultrahigh-sensitive PCF biosensor for blood component detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 41 publications
(12 citation statements)
references
References 55 publications
0
8
0
Order By: Relevance
“…Boundary conditions are introduced to numerically solve the problem, and then the field function and the required performance parameters are obtained for the whole simulated domain. To simulate the realistic case and achieve convergence, a special dielectric layer with a thickness of 10% of the fiber radius is set at the fiber periphery, so that THz waves leaking into the cladding can pass through the interface and enter a perfect matched layer (PML) without reflection [ 14 , 31 ]. Here, the radius of the fiber is 1400 μm and the PML is 140 μm in thickness.…”
Section: Design Approach and Theoretical Derivationsmentioning
confidence: 99%
“…Boundary conditions are introduced to numerically solve the problem, and then the field function and the required performance parameters are obtained for the whole simulated domain. To simulate the realistic case and achieve convergence, a special dielectric layer with a thickness of 10% of the fiber radius is set at the fiber periphery, so that THz waves leaking into the cladding can pass through the interface and enter a perfect matched layer (PML) without reflection [ 14 , 31 ]. Here, the radius of the fiber is 1400 μm and the PML is 140 μm in thickness.…”
Section: Design Approach and Theoretical Derivationsmentioning
confidence: 99%
“…The relative sensitivity coefficient is used to determine how much the evanescent field interacts with the analyte present in the core. Beer Lambert's law relates the quantity of light that is absorbed by the analyte present in the core, and it is given by [56]: I(f)=I0(f)eramlc $I(f)={I}_{0}(f){e}^{-r{a}_{m}{l}_{c}}$ …”
Section: Performance Analysismentioning
confidence: 99%
“…When the incident light wavelength overlap with the HC-MOF bandgaps, the light will be reflected by the cladding and guided in the fiber core (Russell 2003 ; Rahaman et al 2022 ). HC-MOFs have been used extensively in various applications including nonlinear optics (Azhar et al 2013 ), imaging and spectroscopy (Stawska and Izabela 2018 ; Andreana et al 2019 ), high-intensity laser transmission (Couny et al 2007 ), and biosensing (Islam et al 2021 ; Hossain et al 2020 ). In specific, HC-MOFs are used for numerous bio sensing applications such as Cancer Cell sensing (Ahmed et al 2019 ), Pregnancy sensing (Jabin et al 2019 ), hemoglobin detection (Mitu et al 2021 ) and Covid-19 detection(Patel et al 2022 ).…”
Section: Introductionmentioning