2019
DOI: 10.1016/j.ijepes.2019.03.006
|View full text |Cite|
|
Sign up to set email alerts
|

Design of a novel robust current controller for grid-connected inverter against grid impedance variations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0
3

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(15 citation statements)
references
References 24 publications
0
12
0
3
Order By: Relevance
“…In the grid-tied and islanded mode, apart from the synchronization method, the same procedure is applied in many papers using traditional dual loop PID+R controllers. A reference current or voltage value is tracked by an outer voltage loop and inner current loop in abc (natural frame), dq (synchronous reference frame), or αβ (stationary reference frame) frame in the single or three-phase and the s or z domain [9], [148], [149], [158]- [161], [150]- [157].…”
Section: Pid+r Technique (Dual Loop)mentioning
confidence: 99%
See 1 more Smart Citation
“…In the grid-tied and islanded mode, apart from the synchronization method, the same procedure is applied in many papers using traditional dual loop PID+R controllers. A reference current or voltage value is tracked by an outer voltage loop and inner current loop in abc (natural frame), dq (synchronous reference frame), or αβ (stationary reference frame) frame in the single or three-phase and the s or z domain [9], [148], [149], [158]- [161], [150]- [157].…”
Section: Pid+r Technique (Dual Loop)mentioning
confidence: 99%
“…The results show that the H∞ controller is more robust than MPC. Another study of control parameter roles in the stability of the current-controlled grid-tied inverter in the grid impedance variation condition was conducted in [161]. The decomposition method clarifies the stable region in the z domain in the grid impedance uncertainty.…”
Section: E Robustness Analysismentioning
confidence: 99%
“…Entretanto tal filtro apresenta uma ressonância inerente, devido aos três elementos passivos em sua estrutura, o que causa problemas de instabilidade e oscilações nas correntes injetadas na rede. Ainda, tal problema é acentuado pela característica variante no tempo da rede elétrica, o que afeta a ressonância do filtro [3].…”
Section: Introductionunclassified
“…It was shown that once a set of smooth current references were provided to the controller, the inverter maintained nominal performance during a sudden increase of the grid impedance. Similarly, other types of controllers implemented in the αβ-frame including a robustly tuned Proportional Resonant (PR) controller, and a combination of PR and a lead compensator are proposed in [16,17]. While these solutions in the αβ-frame may be promising, VIR implementation requires determination of the grid voltage angle, and the synchronous reference frame PLL (SRF-PLL) is widely adopted in three phase inverters for this purpose [18].…”
Section: Introductionmentioning
confidence: 99%