2015
DOI: 10.1109/tie.2015.2404317
|View full text |Cite
|
Sign up to set email alerts
|

Design of a Generalized Control Algorithm for Parallel Inverters for Smooth Microgrid Transition Operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
54
0
3

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 131 publications
(62 citation statements)
references
References 34 publications
0
54
0
3
Order By: Relevance
“…If the alternate operating mode is not successful because of an incidence, the microgrid will become the shutdown mode and lead to the microgrid blackout. Subsequently, the microgrid will resume operation when the main grid returns to the normal state (grid-connected mode) or when the microgrid can properly manage the energy supply to the local load (islanded mode) [24]. In the islanded mode, if the capacity of the DG unit is not sufficient for the local load demand, and the BESS controller cannot respond instantaneously, the microgrid will lose its stability operations and enter the shutdown mode.…”
Section: The Perspective Of Microgridmentioning
confidence: 99%
“…If the alternate operating mode is not successful because of an incidence, the microgrid will become the shutdown mode and lead to the microgrid blackout. Subsequently, the microgrid will resume operation when the main grid returns to the normal state (grid-connected mode) or when the microgrid can properly manage the energy supply to the local load (islanded mode) [24]. In the islanded mode, if the capacity of the DG unit is not sufficient for the local load demand, and the BESS controller cannot respond instantaneously, the microgrid will lose its stability operations and enter the shutdown mode.…”
Section: The Perspective Of Microgridmentioning
confidence: 99%
“…1676, compatible with all the microgrid operation modes [5]. The highest layer, the system control layer, is implemented in microgrid central controller (energy management system (EMS)).…”
Section: A Generalized Control Architecture For Dgs In Microgridmentioning
confidence: 99%
“…1). During that time, a controller is needed to preserve the stability and reliability of each unit to achieve seamless mode transfer, which is adopted by many researchers [7]- [20]. A nonlinear sliding-mode voltage controller and adaptive power sharing controller are proposed in [7].…”
Section: Introductionmentioning
confidence: 99%
“…A dispatch unit is chosen in [19] to facilitate the interconnection with utility and to achieve smooth transition between the operating modes. Furthermore, a hierarchical control is proposed in [20] to simplify the seamless transition. However, DC link stability has not been emphasized.…”
Section: Introductionmentioning
confidence: 99%