2015
DOI: 10.3390/en8031606
|View full text |Cite
|
Sign up to set email alerts
|

Design of a Four-Branch LCL-Type Grid-Connecting Interface for a Three-Phase, Four-Leg Active Power Filter

Abstract: Abstract:Compared with the three-phase, two-split-capacitor active power filter (3P2C-APF), the three-phase, four-leg active power filter (3P4L-APF) has been widely used in three-phase, four-wire grid utility for power quality control due to its numerous advantages, such as higher current output capability, particularly in phase N, lower current and easier voltage control on the DC-side. However, designing the grid-connecting interface, which is between the voltage source converter (VSC) and grid utility, is r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 16 publications
(36 reference statements)
0
10
0
Order By: Relevance
“…Table 2 lists each component used for the proposed SAPF. The detailed calculations for determining the values of the dc link capacitor, dc/dc boost inductor and filtering inductor was based on [53,54]. Specifically, for the dc link capacitor, a bigger value is needed for minimizing the ripple voltage [52,55].…”
Section: Simulation Resultsmentioning
confidence: 99%
“…Table 2 lists each component used for the proposed SAPF. The detailed calculations for determining the values of the dc link capacitor, dc/dc boost inductor and filtering inductor was based on [53,54]. Specifically, for the dc link capacitor, a bigger value is needed for minimizing the ripple voltage [52,55].…”
Section: Simulation Resultsmentioning
confidence: 99%
“…Their compensation characteristics are strongly influenced by supply impedance and they are highly susceptible to series and parallel resonances with the supply and load impedance. The APFs, which are based on power electronics, can overcome the above drawbacks of PPFs [3,4]. Additionally, APFs are more flexible and efficient compared with PPFs.…”
Section: Introductionmentioning
confidence: 99%
“…Most research works on SAPF adopt a general two-level voltage source inverter (VSI) topology [12][13][14]. However, multilevel inverters which have been reported to be superior to conventional two-level inverters [15][16][17] in term of output voltage quality (less harmonic distortions), are acknowledged as better alternative.…”
Section: Introductionmentioning
confidence: 99%