2011 IEEE Applied Power Electronics Colloquium (IAPEC) 2011
DOI: 10.1109/iapec.2011.5779864
|View full text |Cite
|
Sign up to set email alerts
|

Design of a current mode PI controller for a single-phase PWM inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(17 citation statements)
references
References 7 publications
0
12
0
2
Order By: Relevance
“…In order to obtain the preferable value of switching frequency, the value of the cut-off frequency should be lower or equal to the value of switching frequency, Fs divided by 10. The value of capacitor for the filter can be obtained after attenuating Equations (10) and (11). the capacitor current.…”
Section: Energy-saving Circuitmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to obtain the preferable value of switching frequency, the value of the cut-off frequency should be lower or equal to the value of switching frequency, Fs divided by 10. The value of capacitor for the filter can be obtained after attenuating Equations (10) and (11). the capacitor current.…”
Section: Energy-saving Circuitmentioning
confidence: 99%
“…This current is added to the load current in order to obtain the current reference. This reference current value will be compared to the current from the inverter producing the error value to be fed into the second loop in the cascade system [11].…”
Section: Energy-saving Circuitmentioning
confidence: 99%
“…that feedback linearizes the first equation of (1). From equations (24), (26) and (28) we can propose the control law:…”
Section: B Control Law For Pvmentioning
confidence: 99%
“…The model is derived under the assumption that all the converter elements are ideal. The PI controllers are designed using method cited in ( [26], [27]).…”
Section: Comparison With Pi Controlmentioning
confidence: 99%
“…The diagram-aided method is basically a computer-based single-input, single-output (SISO) tool in MATLAB to obtain the parameters with the help of defining the system transfer function. The SISO tool gives the bode and root locus plot where the poles and zeros can be adjusted to get the desired output and corresponding parameters of the controller [21]. Now the impact of the grid impedance on the stability of the voltage control loop in the conventional scheme is analyzed.…”
Section: Conventional Control Schemementioning
confidence: 99%