2018
DOI: 10.1002/eej.23117
|View full text |Cite
|
Sign up to set email alerts
|

Design of a coil geometry for generating magnetic field to evaluate biological effects at 85 kHz

Abstract: In recent years, the use of induction‐heating systems has increased and wireless power transmission (WPT) systems have been discussed. These applications are installed close to a human body. Therefore, it is important to discuss the effects of alternating magnetic fields and to evaluate electromagnetic interference. This paper discusses the design procedure of a magnetic field generator to evaluate the electromagnetic interference at 85 kHz that is being studied in WPT systems for EV and HEV. The magnetic fiel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 14 publications
(30 reference statements)
0
5
0
Order By: Relevance
“…We modified the IF-MF exposure system used in previous studies [ 9 ] and constructed a new exposure system [ 10 ]. This system consisted of a power supply, inverter, capacitor and solenoid coil equipped with a chiller for cooling ( Fig.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…We modified the IF-MF exposure system used in previous studies [ 9 ] and constructed a new exposure system [ 10 ]. This system consisted of a power supply, inverter, capacitor and solenoid coil equipped with a chiller for cooling ( Fig.…”
Section: Methodsmentioning
confidence: 99%
“…A schematic of the IF-MF exposure system was provided by Matsubara et al. [ 10 ]. The system has an air-core coil to generate IF-MF.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The loops parameters are determined by considering the following equations, peak value V L of coil terminal voltage is expressed by [13].…”
Section: Loop Designmentioning
confidence: 99%
“…The coil structure, inductance and flux density at the loop central point, targeting the optimal loop structure for the laboratory generation of magnetic field. Inductance of magnetic generation loop consists of internal inductance L in and external inductance L e and the interwinding mutual inductance M. the equations below explain the analysis parameters to determine the internal inductance, wiring length and the permeability of the vacuum [13].…”
Section: Loop Designmentioning
confidence: 99%