1949
DOI: 10.1049/jiee-2.1949.0133
|View full text |Cite
|
Sign up to set email alerts
|

Design of a capacitor voltage transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1953
1953
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…The equivalent load of the circuit inside the display terminal is dependent on time under different working modes, which may lead VDR of the CVD to change. Thus, a compensation reactor L is chosen to eliminate this adverse change, and it is similar with the function of reactors in capacitor voltage transformers [30]. The inductance of the reactor is in resonance with the sum of the two capacitors C H and C L at power frequency 50 Hz.…”
Section: Power Supply For Display Terminalmentioning
confidence: 99%
“…The equivalent load of the circuit inside the display terminal is dependent on time under different working modes, which may lead VDR of the CVD to change. Thus, a compensation reactor L is chosen to eliminate this adverse change, and it is similar with the function of reactors in capacitor voltage transformers [30]. The inductance of the reactor is in resonance with the sum of the two capacitors C H and C L at power frequency 50 Hz.…”
Section: Power Supply For Display Terminalmentioning
confidence: 99%
“…In 1936, being an expectation or proposition, the CVT being only a term was presented [4], with no claim made for presenting any new principles of design. One of its earliest practical devices was given and published in 1949 [5]. Today the CVT has been widely used as an instrument transformer in power systems (Fig.…”
Section: Basics Of the Mutual Capacitormentioning
confidence: 99%
“…[2] studied the influence of linear and nonlinear loads on active energy measurement,deduced the electric energy consumed by two kinds of load,and put forward the irrationality of measurement mode by simulating with real-time digital system.There are few studies on the influence of harmonics on voltage transformer.Ref. [3] gave the equivalent circuit of captive voltage transformer(CVT) and calculated the error under different loads.As for the research on electromagnetic current transformer(ECT),Ref. [4] calculated the excitation impedance and winding distributed capacitance of ECT,established the ECT model of high frequency,but it is not accurate enough in lower harmonics after simulating.…”
Section: Introductionmentioning
confidence: 99%