2019
DOI: 10.1109/tps.2018.2890307
|View full text |Cite
|
Sign up to set email alerts
|

Design, Development, and Operation of Seven Channels’ 100-GHz Interferometer for Plasma Density Measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 11 publications
0
12
0
Order By: Relevance
“…The measuring systems used in these experiments include various external magnetic sensors for current, voltage plasma position, stored energy and Mirnov oscillation measurements [21]. Microwave interferometer is used for electron density measurement [22] and electron temperature is deduced from the Soft X-ray emission measurement using foil-ratio technique [24]. PMT-filter based spectroscopic systems and visible spectrometers are used for Hα and low Z impurity emission monitoring as well as plasma column boundary position measurements [10,23].…”
Section: Aditya-u Operations and Experimental Progressmentioning
confidence: 99%
“…The measuring systems used in these experiments include various external magnetic sensors for current, voltage plasma position, stored energy and Mirnov oscillation measurements [21]. Microwave interferometer is used for electron density measurement [22] and electron temperature is deduced from the Soft X-ray emission measurement using foil-ratio technique [24]. PMT-filter based spectroscopic systems and visible spectrometers are used for Hα and low Z impurity emission monitoring as well as plasma column boundary position measurements [10,23].…”
Section: Aditya-u Operations and Experimental Progressmentioning
confidence: 99%
“…The rotation measurements are carried out in discharges in the toroidal belt-limiter configuration, and the plasma and machine parameters of the discharges analyzed are as follows: current Ip = ~100 kA and plasma duration of ~250-300 ms with line-averaged electron density ne = 1-6 × 10 19 m 3 and central electron temperature T e in the range of 500 eV-1 keV. The central line-integrated electron density has been measured using a microwave interferometer diagnostic [28], whereas the central electron temperature has been measured using soft x-ray diagnostics.…”
Section: Experimental Set-upmentioning
confidence: 99%
“…During the present experiments, the central chord-averaged density has been measured using a 100 GHz heterodyne microwave interferometer 36 . For measuring the radial electron density profile, a four-channel homodyne microwave interferometer system, having the viewing chords passing through 0, 7, 14 and 21 cm of plasma minor radius with a temporal resolution of ∼10 μs has been used 37 . An Abel-like matrix inversion technique is used to get the radial profile of electron density from the chord averaged measurement 38 .…”
Section: Methodsmentioning
confidence: 99%