2017
DOI: 10.1016/j.nima.2016.12.065
|View full text |Cite
|
Sign up to set email alerts
|

Design, construction and performance evaluation of the target tissue thickness measurement system in intraoperative radiotherapy for breast cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…Herskind's Radiobiological Models (18) attempt to explain why the distribution of kV dose can provide comparable treatment to electrons. TARGIT's final results (20)(21)(22) and perchance additional studies can also help in proving the equivalence.…”
Section: Pre-planned Dose In Iort Uncertainties and Deviationsmentioning
confidence: 97%
See 2 more Smart Citations
“…Herskind's Radiobiological Models (18) attempt to explain why the distribution of kV dose can provide comparable treatment to electrons. TARGIT's final results (20)(21)(22) and perchance additional studies can also help in proving the equivalence.…”
Section: Pre-planned Dose In Iort Uncertainties and Deviationsmentioning
confidence: 97%
“…For this reason, it is necessary to have documentation and comprehensive reporting. This record should include geometry and anatomical relations of the treatment site, shielded areas, if any, and applicator definition such as shape, size, position, angle, and beam energy (20,21). In short, we are at the beginning of the journey in IORT treatment planning development.…”
Section: Treatment Planning Systems For Iortmentioning
confidence: 99%
See 1 more Smart Citation
“…Intraoperative Radiation Therapy (IORT) is a specific method that may transfer sufficient and monotonous high-dose radiation to the tumor bed during surgery [ 1 - 4 ]. This treatment method decreases local recurrence risk, and healthy tissue receives a minor dose due to its localized radiation [ 5 , 6 ]. The physician’s serious effort is impressively sending an intensive dose to the desired tissue while decreasing damage to healthy tissues surrounding the region of interest [ 7 , 8 ].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the thickness of target tissue with unacceptable is measured using a needle [ 33 ]; intraoperative ultrasound is another method to specify the thickness [ 2 , 15 , 23 ]. A novel electronic board was designed to determine the thickness of target tissue based on measuring the electron flux at the board with an accuracy better than the others [ 5 ]. This study aimed to investigate a method to compute the thickness of target tissue in the IORT routine.…”
Section: Introductionmentioning
confidence: 99%