Abstract: Abstract-A Transverse Electromagnetic Mode (TEM) cell is an interesting option for studying the biological effects of radiofrequency radiation at reduced scale (in vitro studies).Controlled and well-characterized exposure conditions are essential for a conclusive investigation: the biological sample is exposed to a uniform incident electromagnetic wave and the dose of absorbed radiation is precisely determined and correlated with the effect. Unfortunately, experimental dosimetry is often unavailable or inappli… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(13 citation statements)
references
References 24 publications
0
13
0
Order By: Relevance
“…For the experimental SAR determination, we used a formula connecting the absorbed power (P a ) with the input power P in [19]: (1) where S 11 is the input port voltage reflection coefficient and S 21 is the forward voltage gain coefficient. These scattering parameters were experimentally measured in two cases: 1) in the case when the TEM cell was unloaded by the blood samples (the absorption was due to the cell walls, ferrite tiles, radio-absorbing material and empty containers of the blood samples); 2) in the second case when the cell was loaded by the blood samples.…”
Section: Methodsmentioning
confidence: 99%
“…For the experimental SAR determination, we used a formula connecting the absorbed power (P a ) with the input power P in [19]: (1) where S 11 is the input port voltage reflection coefficient and S 21 is the forward voltage gain coefficient. These scattering parameters were experimentally measured in two cases: 1) in the case when the TEM cell was unloaded by the blood samples (the absorption was due to the cell walls, ferrite tiles, radio-absorbing material and empty containers of the blood samples); 2) in the second case when the cell was loaded by the blood samples.…”
Section: Methodsmentioning
confidence: 99%
“…Conductor thickness is chosen as 2 mm again. TE mode cutoff frequencies can be calculated easily and new operating frequency range will be between 1 and 2 GHz with new TEM Cell dimensions. When all these modifications are applied to draw all half TEM Cell, simulation results are shown in Figures and .…”
Section: Design Of a Tem Cellmentioning
confidence: 99%
“…Return loss of TEM Cell created using [2]. to be chosen carefully since there is too much loss between the probes.…”
Section: Figure 22mentioning
confidence: 99%
“…For in vitro studies of RF-induced biological effects at reduced scale, the Transverse Electromagnetic (TEM) cell is a commonly used delivery device [12][13][14][15][16]. An opened TEM cell with an aperture in the center of the lower plate has been proposed for real-time microscopic observation of exposed cells [17].…”
Section: Introductionmentioning