2018 International Conference on Communication Information and Computing Technology (ICCICT) 2018
DOI: 10.1109/iccict.2018.8325868
|View full text |Cite
|
Sign up to set email alerts
|

Design and simulation of four-leg based three-phase four-wire shunt active power filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 11 publications
0
4
0
1
Order By: Relevance
“…The reverse current produced by the inverter is introduced into the system to compensate for the harmonic currents; these currents are obtained using the p-q theory. To achieve neutral current compensation, two main topologies are used: (i) inverters to generate voltages; (ii) Inverters with two midpoint capacitors and a four-arm inverter (used as an active filter) (Barva et al 2018;Kumar et al 2022;Collins et al 2022;Zhang et al 2022;Challa et al 2022). Mainly, the four-wire shunt active filters, with three phases, have three branches with two switches controlled by the PWM technique and the fourth leg is on standby and has two switches controlled by the PWM technique.…”
Section: Description and Modeling Of The Studied Microgrid Systemmentioning
confidence: 99%
“…The reverse current produced by the inverter is introduced into the system to compensate for the harmonic currents; these currents are obtained using the p-q theory. To achieve neutral current compensation, two main topologies are used: (i) inverters to generate voltages; (ii) Inverters with two midpoint capacitors and a four-arm inverter (used as an active filter) (Barva et al 2018;Kumar et al 2022;Collins et al 2022;Zhang et al 2022;Challa et al 2022). Mainly, the four-wire shunt active filters, with three phases, have three branches with two switches controlled by the PWM technique and the fourth leg is on standby and has two switches controlled by the PWM technique.…”
Section: Description and Modeling Of The Studied Microgrid Systemmentioning
confidence: 99%
“…Formula (22) is subjected to Laplace transform, and the solvedẑ 1 ,ẑ 2 ,ẑ 3 are brought into Formula (21) to obtain Formula (23). The system is regarded as a subsystem with two inputs and one output, where the inputs are r and y and the outputs are u.…”
Section: Frequency Domain Analysismentioning
confidence: 99%
“…However, the construction of nonlinear functions and complex parameters tuning limits the widespread use of nonlinear ADRC in industry. To this end, ADRC has been simplified to linear form (LADRC) in [18] and has been used in power systems and power electronics [19][20][21].The above method only considers that current distortion is not severe, but most of the loads are nonlinear in practical production. If grid-connected current control strategy is used in the power system without harmonic suppression, the power quality at PCC will not meet the standards set by the International Electrotechnical Commission (IEC).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Devido a maior abrangência e aceitabilidade das topologias VSC convencionais [57][58][59][60], que fazem uso de um capacitor para composição do elo CC, nesta dissertação ter-se-á apenas aplicações e estudos em conversores com esta estratégia de conversão.…”
Section: Fig 34 -Diagrama De Um Filtro Ativo Shunt Do Tipo Vscunclassified