Medical Imaging 2005: Physics of Medical Imaging 2005
DOI: 10.1117/12.595833
|View full text |Cite
|
Sign up to set email alerts
|

Design and performance of the prototype full field breast tomosynthesis system with selenium based flat panel detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

3
73
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 70 publications
(76 citation statements)
references
References 0 publications
3
73
0
Order By: Relevance
“…The measured MTFs for the same spatial frequencies in our study were 0.81 and 0.59 for 2 D, 0.66 and 0.34 for DBT scan, and 0.58 and 0.13 for the reconstructed plane in the LR direction, respectively. Our MTFs were also comparable to results from Baorui et al for the prototype Hologic breast tomosynthesis system [17]. The measured NNPS in this study was comparable to the NNPS measured by Marshall et al for Siemens Mammomat InspirationTomo [11].…”
supporting
confidence: 79%
See 2 more Smart Citations
“…The measured MTFs for the same spatial frequencies in our study were 0.81 and 0.59 for 2 D, 0.66 and 0.34 for DBT scan, and 0.58 and 0.13 for the reconstructed plane in the LR direction, respectively. Our MTFs were also comparable to results from Baorui et al for the prototype Hologic breast tomosynthesis system [17]. The measured NNPS in this study was comparable to the NNPS measured by Marshall et al for Siemens Mammomat InspirationTomo [11].…”
supporting
confidence: 79%
“…Most of these studies were carried out using a Siemens Mammomat prototype tomosynthesis system (Siemens, Erlangen, DE). To our knowledge, the first physical image quality measurements for the Selenia Dimensions breast tomosynthesis system were carried out by Hologic employees [16,17]. Marshall and Bosmans recently published a study of system sharpness measurement (MTF) comparing Siemens Inspiration and Hologic Selenia Dimensions DBT systems [18].…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…It is really challenging to differentiate between the malignant and non-malignant behaviors from the film base masses, lesions, micro and macro calcifications of human breast tissues due to some cultural, regional and socio-economic problems which are likely to be found to form the dense and tender tissues because race, gender, occupation, geographic conditions, social system and other contributing factors create [7], [8] lots of variations in the composition of human breast tissues. On the other side there are lots of limitations associated with mammogram image accusation process due to improper acquisition processes caused by unavoidable technological noise seen in medical images [9], [10]. This create lots of confusions for radiologist to interpret the particular type of malignant behaviors and sometime ultrasound guided biopsies are recommended for deep analysis of the disease and results may reveal no malignancy.…”
Section: Introductionmentioning
confidence: 99%
“…[5][6][7][8][9][10] To generate the limited angle series of projection images, a mammography x-ray tube moves along an arc above the partially compressed breast. The scanners by Siemens and Hologic operate in a continuous motion mode.…”
Section: Introductionmentioning
confidence: 99%