2015
DOI: 10.1109/tns.2015.2468182
|View full text |Cite
|
Sign up to set email alerts
|

Design and Performance of the ARIANNA HRA-3 Neutrino Detector Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
71
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 53 publications
(74 citation statements)
references
References 17 publications
0
71
0
Order By: Relevance
“…The operation of the ARIANNA test bed at Moore's Bay, since its completion in November 2014, has provided a robust proof of concept for an in-situ, radio-based UHE neutrino detector. Iterative improvements in data acquisition and power systems since the first ARIANNA prototypes [15] and initial test bed stations [29] have improved reliability and livetime. We have presented the analysis of 4.5 years of data, leading to a 90% confidence upper limit on the diffuse neutrino flux of E 2 Φ = 1.3 × 10 −6 GeVcm −2 s −1 sr −1 for a decade wide logarithmic bin centered at a neutrino energy of 10 18 eV.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The operation of the ARIANNA test bed at Moore's Bay, since its completion in November 2014, has provided a robust proof of concept for an in-situ, radio-based UHE neutrino detector. Iterative improvements in data acquisition and power systems since the first ARIANNA prototypes [15] and initial test bed stations [29] have improved reliability and livetime. We have presented the analysis of 4.5 years of data, leading to a 90% confidence upper limit on the diffuse neutrino flux of E 2 Φ = 1.3 × 10 −6 GeVcm −2 s −1 sr −1 for a decade wide logarithmic bin centered at a neutrino energy of 10 18 eV.…”
Section: Resultsmentioning
confidence: 99%
“…The ARIANNA DAq mainboard is designed around the Synchronous Sampling plus Triggering (SST) chip [29,34,35]. Incoming signals are sampled at 2 GSa/s and held in a 256 sample circular buffer, which is read out when a triggering condition is met.…”
Section: Data Acquisitionmentioning
confidence: 99%
“…This is due to the smaller accuracy of the fits to the electromagnetic and hadronic vector potentials in Eqs. (14) and (15) in the time range outside the window (−0.5, 0.5) ns. An improved fit or an interpolation of the MC results instead of the fit is expected to increase the accuracy of our methodology even in the region where the amplitude of the vector potential is negligible compared to that at the peak.…”
Section: Discussionmentioning
confidence: 99%
“…Due to the smaller accuracy of the fits to the vector potentials given in Eqs. (14) and (15) in the time region outside the (−0.5, 0.5) ns window, the accuracy between the model and the full MC simulations drops to about 20% in the onset and in the latest times of the pulse. However, the amplitude also drops by at least three orders of magnitude in these regions and it is not expected to be relevant for practical purposes.…”
Section: Askaryan Emission In Neutrino-induced Showersmentioning
confidence: 95%
“…The full HRA system also serves to test and verify the functionality of all technical systems [7]. An important challenge is the power system.…”
Section: The Hexagonal Radio Arraymentioning
confidence: 99%