2018
DOI: 10.1016/j.ijheatmasstransfer.2017.09.080
|View full text |Cite
|
Sign up to set email alerts
|

Design and performance evaluation of a multilayer fixed-bed binder-free desiccant dehumidifier for hybrid air-conditioning systems: Part II – Theoretical analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…Hsu et al [56] and Lee et al [57] discuss the application of a composite Langmuir-Sips isotherm on water and organic compounds, respectively. Lee et al [57] employs this model as it can represent equilibrium data by Langmuir isotherm at low pressure and Sips isotherm at moderate pressure to account for capillary condensation.…”
Section: Langmuir-sips Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…Hsu et al [56] and Lee et al [57] discuss the application of a composite Langmuir-Sips isotherm on water and organic compounds, respectively. Lee et al [57] employs this model as it can represent equilibrium data by Langmuir isotherm at low pressure and Sips isotherm at moderate pressure to account for capillary condensation.…”
Section: Langmuir-sips Modelmentioning
confidence: 99%
“…The Langmuir-Sips equation finds application also in the adsorption of vapors of polar and nonpolar organic compounds on mesoporous silicate and the water adsorption on a silicabased high-purity spherical gel [56,57]. The latter is a Type-V isotherm, as shown in Figure 15.…”
Section: Langmuir-sips Modelmentioning
confidence: 99%
“…As previously described, the adsorption isotherms for most of the conventional isotherm models are applicable either only in a very limited pressure range or a wide range of pressures with limited prediction accuracy, limiting their utility in adsorption-isotherm modeling. Therefore, a hybrid isotherm model serves as an alternative, overcoming the aforementioned drawbacks of the conventional isotherm model, and several studies have been conducted by implementing the hybrid isotherm model. , In this study, a hybrid isotherm model consisting of the Langmuir and Sips equations was proposed. The Langmuir isotherm is the simplest isotherm model that is valid for describing micropore filling and monolayer adsorption.…”
Section: Resultsmentioning
confidence: 99%
“…11 The desiccant air-conditioning (DAC) has showed reasonable cooling effect in humid climatic conditions. [12][13][14][15][16][17][18] A typical DAC system comprises of desiccant dehumidification unit (to achieve latent load of air-conditioning (AC)) and a low-cost cooling unit preferably evaporative cooling (to achieve sensible load of AC). Therefore, it controls latent and sensible load of AC distinctly.…”
Section: Introductionmentioning
confidence: 99%