2006
DOI: 10.1109/tpwrd.2005.861332
|View full text |Cite
|
Sign up to set email alerts
|

Design and Performance Evaluation of Subsynchronous Damping Controller With STATCOM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
86
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 172 publications
(86 citation statements)
references
References 14 publications
0
86
0
Order By: Relevance
“…The time period in a cycle during which the converter pole voltage is zero is 4β ω 0 . The three-level converter topology greatly reduces the harmonic distortion on the ac side [5], [8], [9] and [10]. Here the STATCOM is realized by a combination 24-pulse three level configuration.…”
Section: Modeling Of Statcom With Three Levelmentioning
confidence: 99%
See 2 more Smart Citations
“…The time period in a cycle during which the converter pole voltage is zero is 4β ω 0 . The three-level converter topology greatly reduces the harmonic distortion on the ac side [5], [8], [9] and [10]. Here the STATCOM is realized by a combination 24-pulse three level configuration.…”
Section: Modeling Of Statcom With Three Levelmentioning
confidence: 99%
“…A detailed three-phase model of STATCOM is developed by modeling the converter operation by switching functions [5], [10]. A.…”
Section: Modeling Of Statcom With Three Levelmentioning
confidence: 99%
See 1 more Smart Citation
“…However, generator shaft of a thermal plant has a great opportunity to exchange sub-synchronous energy with the series compensation capacitor and then sub-synchronous resonance (SSR) occurs [4][5][6][7][8]. Since electric strength between AC Buses, which is decided by short-circuit capacity of an equivalent system, can change the resonance frequency of the system and damping characteristics of SSR [9][10][11][12], at the system planning stage it is critical to ensure the short-circuit capacity does not make contributions to exciting SSR.…”
Section: Introductionmentioning
confidence: 99%
“…CrossCheck date: 8 February 2017 FACTS like static synchronous compensator (STAT-COM) and static synchronous series compensator (SSSC) have been used to mitigate SSR in previous literatures [14][15][16]. Equipped with back-to-back voltage source converters (VSC), proper supplementary control of UPFC can be used to enhance the stability of the power system [17].…”
Section: Introductionmentioning
confidence: 99%