Design and performance evaluation of a compact, large-area PET detector module based on silicon photomultipliers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(12 citation statements)
references
References 12 publications
0
12
0
Order By: Relevance
“…Thus, the active area of the detector is 41.2 × 91.5 mm 2 , which is larger than other SiPM-based detector modules reported in the literature (Chagani 2009, Schaart 2009, Yamamoto 2010, Llosa 2011, Zorzi 2011,Schulz 2011, Wang 2012, Yoon 2012). The LYSO array was coupled to two SensL ArraySL-4p9s (SensL Technologies, LTD., Cork Ireland).…”
Section: Methodsmentioning
confidence: 77%
See 1 more Smart Citation
“…Thus, the active area of the detector is 41.2 × 91.5 mm 2 , which is larger than other SiPM-based detector modules reported in the literature (Chagani 2009, Schaart 2009, Yamamoto 2010, Llosa 2011, Zorzi 2011,Schulz 2011, Wang 2012, Yoon 2012). The LYSO array was coupled to two SensL ArraySL-4p9s (SensL Technologies, LTD., Cork Ireland).…”
Section: Methodsmentioning
confidence: 77%
“…These devices have higher gain than APDs, comparable to photomultiplier tubes (on the order of 1x10 6 ), and have the same insensitivity to magnetic fields as APDs (Roncali and Cherry 2011). A number of investigators have created MR-compatible PET detector modules from which MRI-PET scanners can be constructed (Chagani 2009, Schaart 2009, Yamamoto 2010, Llosa 2011, Schulz 2011, Zorzi 2011,Wang 2012, Yoon 2012). For example, a group from the Seoul National University constructed a 32.4 × 28.7 mm 2 SiPM-based PET detector module (Yoon 2012).…”
Section: Introductionmentioning
confidence: 99%
“…A row-column readout of the SiPM matrix was used without applying individual signalprocessing channels to each matrix element. Weighting circuits were connected directly to the row and column outputs as proposed by Wang et al (13) but modified to reduce the dark noise. The overlap between the crystals and the SiPM-sensitive areas was determined during design of the SiPM sensors to optimize position encoding.…”
Section: System Descriptionmentioning
confidence: 99%
“…System peak absolute sensitivity is defined as the S A,i at the center of the field of view (13). Total absolute sensitivity (S A,tot ) was calculated using the following equation:…”
Section: Sensitivitymentioning
confidence: 99%
“…Because the size of an individual SiPM is usually small (i.e. or less), many designs combine arrays of SiPMs to make detector modules with larger surface areas [1]- [3]. Often the signals from these SiPMs are multiplexed to reduce the number of data lines leaving each module [4]- [6].…”
Section: Introductionmentioning
confidence: 99%