2022
DOI: 10.1016/j.jmmm.2022.170056
|View full text |Cite
|
Sign up to set email alerts
|

Design and modelling of a controlled saturable inductor for an LCC-S compensated WPT system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 18 publications
0
2
0
Order By: Relevance
“…The AC winding (red), connected to the transmitter side of the system, is located on the central column of the core. The material of the central leg operates in the linear region of the magnetization since no static magnetic field interests this path, and an air gap ensures low AC magnetic field values, even with considerable voltage and current swings of the AC winding [27]. A further advantage of this configuration is that the anti-series connection of the DC windings almost cancels the sum of the induced electromotive force on each by improving the capability of the magnetization control, which is useful for the transmitted power regulation of the system.…”
Section: Structure Of the Controlled Variable Inductormentioning
confidence: 99%
See 2 more Smart Citations
“…The AC winding (red), connected to the transmitter side of the system, is located on the central column of the core. The material of the central leg operates in the linear region of the magnetization since no static magnetic field interests this path, and an air gap ensures low AC magnetic field values, even with considerable voltage and current swings of the AC winding [27]. A further advantage of this configuration is that the anti-series connection of the DC windings almost cancels the sum of the induced electromotive force on each by improving the capability of the magnetization control, which is useful for the transmitted power regulation of the system.…”
Section: Structure Of the Controlled Variable Inductormentioning
confidence: 99%
“…The realized prototype has the specifications reported in Table 2, while Figure 6 reports the measured differential inductance profile. Further details on the inductor design procedures and design verification by means of finite element simulations are described in detail in [27].…”
Section: Structure Of the Controlled Variable Inductormentioning
confidence: 99%
See 1 more Smart Citation
“…In this paper, attention is focused on the Magnetic Control (MC) of the LCC-S compensation. This control consists of exploiting the magnetic saturation of the resonant topology inductor [14]. In fact, by changing the value of the inductance, it is possible to regulate the power transferred to the load [15].…”
Section: Introductionmentioning
confidence: 99%
“…Changing the value of the DC current it is possible to change the point of working along the B-H curve of the material [16]. The principle of operation of the converter has been widely proven in [14]. Anyway, the dynamic control of the system is actually missing in the literature.…”
Section: Introductionmentioning
confidence: 99%