2018
DOI: 10.1016/j.ymssp.2017.05.025
|View full text |Cite
|
Sign up to set email alerts
|

Design and implementation of multichannel global active structural acoustic control for a device casing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 35 publications
(17 citation statements)
references
References 16 publications
0
17
0
Order By: Relevance
“…For practical implementations, distributed control using multiple simpler controllers is preferred. Thus, the control algorithm is explicitly divided into P tasks [17]. They can operate on multiple processing units (processors, cores) in a single system or even independent systems that share some signals: the reference signal, error signals and signals needed for acoustic feedback elimination, if needed.…”
Section: Active Noise Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…For practical implementations, distributed control using multiple simpler controllers is preferred. Thus, the control algorithm is explicitly divided into P tasks [17]. They can operate on multiple processing units (processors, cores) in a single system or even independent systems that share some signals: the reference signal, error signals and signals needed for acoustic feedback elimination, if needed.…”
Section: Active Noise Controlmentioning
confidence: 99%
“…The control system was implemented using a distributed system with four dSPACE DS1104 boards, each realizing individual task of the control algorithm [17]. All boards have synchronized Analog to Digital Converters (ADCs) and Digital to Analog Converters (DACs) using an external trigger.…”
Section: Control Systemmentioning
confidence: 99%
“…Under certain conditions, it can provide global noise reduction with low energy demand. However, this approach is out of the scope of this paper and the reader is referred to other publications dedicated to it [15,16,17,18].…”
Section: The Exemplary Scenariomentioning
confidence: 99%
“…This is a very desirable property of any active noise-reducing system. Efficiency of this method was previously investigated by the authors and the results have been reported in multiple publications [12][13][14]. However, in the previous research, the active casing was placed distant from the walls of the room the casing was enclosed by.…”
Section: Introductionmentioning
confidence: 99%