Design and implementation of a new cable‐driven robot for MRI‐guided breast biopsy

Abstract: Background Breast cancer is one of the most common cancer diagnosed among US women. Early and accurate diagnosis using breast biopsy techniques is essential in detecting cancer. Methods In this paper, we present a new cable‐driven robot for MRI‐guided breast biopsy. A compact three degree‐of‐freedom (DOF) semi‐automated robot driven by ultrasonic motors is designed with non‐magnetic materials. Next, a novel insertion trajectory planning algorithm based on the breast holder that we created is proposed and desig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 34 publications
0
10
0
Order By: Relevance
“…The encoder with high resolution can better ensure the puncture accuracy. Liu et al 43 used an optical fiber encoder to obtain the angular displacement information of the robot’s rotational degrees of freedom. The data is transmitted to the control system, which contributes to the error compensation.…”
Section: Mri-guided Breast Intervention Robotmentioning
confidence: 99%
See 1 more Smart Citation
“…The encoder with high resolution can better ensure the puncture accuracy. Liu et al 43 used an optical fiber encoder to obtain the angular displacement information of the robot’s rotational degrees of freedom. The data is transmitted to the control system, which contributes to the error compensation.…”
Section: Mri-guided Breast Intervention Robotmentioning
confidence: 99%
“…Because the piezo-ultrasonic actuation is placed outside the MRI equipment, the robot structure can be designed more compact, which helps the robot to adapt to the narrow workspace. An MRI-guided breast biopsy robot was introduced by Liu et al 43 The robot is designed as a 3-DOF compact robot, which is driven by piezo-ultrasonic motor through cable transmission. In the research on the transmission method of minimally invasive surgical robots, the tendon transmission gets more attention.…”
Section: Mri-guided Breast Intervention Robotmentioning
confidence: 99%
“…6 Liu et al proposed a new cable-driven robot for MRI-guided breast biopsy. 7 The robot is a compact three-DOF semi-automatic robot driven by an ultrasonic motor. Chan et al designed an image-guided breast biopsy robot.…”
Section: Related Workmentioning
confidence: 99%
“…Yang et al developed a pneumatically driven robot to perform breast biopsy under magnetic resonance imaging (MRI) and achieved a slow and smooth movement 6 . Liu et al proposed a new cable‐driven robot for MRI‐guided breast biopsy 7 . The robot is a compact three‐DOF semi‐automatic robot driven by an ultrasonic motor.…”
Section: Introductionmentioning
confidence: 99%
“…7. Liu et al[58] applied a cable transmission system actuated by ultrasonic motors to a robotic system and developed a robotic prototype manufactured with nylon to meet the MRI compatibility requirements.…”
mentioning
confidence: 99%