Design and Implementation of a Parallel-Connected Fault Current Attenuator for Power Distribution Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…Fig. 18 shows the bode plot for the loop gain for the transfer function of the d and q axis positive and negative sequence network (23), (24). The PI controller values selected to ensure the stability of the converter pole are shown in the Tab.…”
Section: B Fault-tolerant Control Methods Verificationmentioning
confidence: 99%
See 1 more Smart Citation
“…Fig. 18 shows the bode plot for the loop gain for the transfer function of the d and q axis positive and negative sequence network (23), (24). The PI controller values selected to ensure the stability of the converter pole are shown in the Tab.…”
Section: B Fault-tolerant Control Methods Verificationmentioning
confidence: 99%
“…The AFEC is the PCS scheme that uses sine triangle PWM for rectifier and inverter operation, thus, a novel fault-tolerant controller is required to operate using sine triangle PWM. Besides, current limiting control techniques should be implemented to control the fault current within the peak limits [24], [25]. In literature, single-switch fault analysis for 3L-NPC pole exists under open and short-circuit conditions [26], [27], but cascaded switch fault condition is not yet discussed.…”
Section: Introductionmentioning
confidence: 99%
“…To facilitate analysis, the line model in this mode is represented as a lumped parameter with resistance and inductance. Upon the current i(t) decreasing to 0, the termination time tm of the energy absorption and the capacitor's voltage Um can be computed [13][14].…”
Section: Number Of Diodes In Series Inmentioning
confidence: 99%
“…For example, system historical data in historical database, real-time telemetry and telecommunication data in real-time database, advanced analysis and calculation results and alarm information, etc. The communication logic completes the uplink and downlink data communication tasks between the Web server and the front-end computer [13]. Uplink data communication means that the front-end processor should inform the system communication module that the system has alarm signals such as switch displacement signal, equipment remote measurement change, equipment exceeding limit or tripping.…”
Section: System Working Principlementioning
confidence: 99%