“…The capacitor-start IM (Fig. 1) has the main phase (including only the main winding) and the auxiliary phase constituted by auxiliary winding in series with a capacitor and a start switch [44], and both are supplied by a single-phase electrical network. The characterized parameters are summarized in Table II.…”
Section: Start-capacitor Single-phase Induction Motor Parametersmentioning
confidence: 99%
“…The capacitor-start IM (Fig. 1) has the main phase (including only the main winding) and the auxiliary phase constituted by auxiliary winding in series with a capacitor and a start switch [44], and both are supplied by a single-phase electrical network. The characterized parameters are summarized in Table II.…”
Section: Start-capacitor Single-phase Induction Motor Parametersmentioning
confidence: 99%
“…A number of publications have been devoted to the selection, design and development of AED for a hermetic compressor of SRU [4][5][6][7][8]. The range of the technical solutions under consideration is quite extensive, but all authors state the idea of the prospect of using the electric drive "frequency converter -three-phase induction motor".…”
Section: Review Of the Literaturementioning
confidence: 99%
“…The range of the technical solutions under consideration is quite extensive, but all authors state the idea of the prospect of using the electric drive "frequency converter -three-phase induction motor". The choice of a control system for the AED of SRU hermetic compressors in [4][5][6][7][8] is suggested to be guided by the following considerations:…”
Section: Review Of the Literaturementioning
confidence: 99%
“…In islanded mode operations like cargo ships, fishing boats, forest agriculture land, the single‐phase motors are supplied by the single‐phase inverters and multilevel inverters to run the machines. Single converter operation of the loads is widely discussed using frequency control method [6, 7]. However, they are facing the serious drawback during the fault or failure of the converter components because the customer cannot install the extra converter.…”
Section: Introductionmentioning
confidence: 99%