Design and implementation of a hand-to-hand multifrequency bioimpedance measurement scheme for Total Body Water estimation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 15 publications
0
7
0
Order By: Relevance
“…The basis of a bioimpedance device is the injection of a current into a biological medium, at one or more frequencies, and the measurement of the voltage produced by the circulation of that current [102]. If the biological medium is the human body, in order to avoid any possible harmful effect, the international safety standards specified in standard IEC 60601 must be strictly complied [31,95,103]. For this reason, most devices inject a current less than 1 mA [45,103].…”
Section: Design and Implementation Of Bioimpedance Instrumentationmentioning
confidence: 99%
See 3 more Smart Citations
“…The basis of a bioimpedance device is the injection of a current into a biological medium, at one or more frequencies, and the measurement of the voltage produced by the circulation of that current [102]. If the biological medium is the human body, in order to avoid any possible harmful effect, the international safety standards specified in standard IEC 60601 must be strictly complied [31,95,103]. For this reason, most devices inject a current less than 1 mA [45,103].…”
Section: Design and Implementation Of Bioimpedance Instrumentationmentioning
confidence: 99%
“…If the biological medium is the human body, in order to avoid any possible harmful effect, the international safety standards specified in standard IEC 60601 must be strictly complied [31,95,103]. For this reason, most devices inject a current less than 1 mA [45,103].…”
Section: Design and Implementation Of Bioimpedance Instrumentationmentioning
confidence: 99%
See 2 more Smart Citations
“…Error sources related to hardware can be removed by considering an appropriate calibration procedure that includes the nonlinearities of the electronic components and their deviations in magnitude and phase, together with the effects of cables and electrodes [47][48][49]. This calibration has been performed using the following semi-automated procedure:…”
Section: Addressing Parasitic Effectsmentioning
confidence: 99%