2022
DOI: 10.1016/j.optlastec.2021.107790
|View full text |Cite
|
Sign up to set email alerts
|

Design and fabrication of wideband chirped tilted fiber Bragg gratings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 18 publications
0
5
0
Order By: Relevance
“…The larger the loss rate of the CTFBG, the stronger the intensity of . However, the intensity of is usually below 20 dB [ 13 , 14 , 17 ] , and thus has a negligible effect on . Furthermore, mainly depends on two aspects.…”
Section: Design and Simulationsmentioning
confidence: 99%
See 2 more Smart Citations
“…The larger the loss rate of the CTFBG, the stronger the intensity of . However, the intensity of is usually below 20 dB [ 13 , 14 , 17 ] , and thus has a negligible effect on . Furthermore, mainly depends on two aspects.…”
Section: Design and Simulationsmentioning
confidence: 99%
“…The second method achieved a high SRS suppression rate by cascading several CTFBGs (multiple CTFBGs). However, this superimposes the insertion losses of individual CTFBGs, resulting in a significant increase in the insertion loss of multiple CTFBGs (>6%) [ 17 ] . Song et al .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Around the central wavelength ~ 13.2 THz downshift from pump wavelength corresponding to the peak Raman gain, the actual linewidth of Raman Stokes is relatively broad [333,335,399]. Thus, there is a problem that the rejection bandwidth of most of the CT-FBGs is not wide enough to cover the whole Raman spectral range at the highpower level, which results in ineradicable sidebands on both sides of the output spectrum [395,397,400]. To broaden the SRS suppression bandwidth of CT-FBGs, a simple tandem writing technique that inscribes two CT-FBGs with different inscription tilt angles has been reported, giving a 3 dB bandwidth of broader than 20 nm [400].…”
Section: Chirped and Tilted Fbg (Ct-fbg) And Long Period Fbg (Lp-fbg)...mentioning
confidence: 99%
“…However, CT-FBGs have some drawbacks such as timeconsuming pretreatment and back-propagating light caused by Bragg reflection, which may seriously affect the laser output power, efficiency and beam quality [401]. Hence, the transmission grating, i.e., LP-FBG [390,393,394,[396][397][398][399][400][401][402][403][404][405], may be a better alternative. LP-FBG can eliminate SRS band by coupling the Stokes light from the core mode to the forward cladding mode, through which the reflected light could be effectively avoided [404], as illustrated in Fig.…”
Section: Chirped and Tilted Fbg (Ct-fbg) And Long Period Fbg (Lp-fbg)...mentioning
confidence: 99%