Design and experimental study of a novel air conditioning system using evaporative condenser at a subway station in Beijing, China

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(9 citation statements)
references
References 34 publications
0
9
0
Order By: Relevance
“…- [56] Integrated Part Load Value IPLV A single-number expressing integrated part-load efficiency of air-conditioning or heat pump equipment weighted on different part-load operation conditions. (100%-, 75%-, 50%-, and 25%-part load) - [24,55] Water Transport Factor WTF…”
Section: Coefficient Of Performance Copmentioning
confidence: 99%
“…- [56] Integrated Part Load Value IPLV A single-number expressing integrated part-load efficiency of air-conditioning or heat pump equipment weighted on different part-load operation conditions. (100%-, 75%-, 50%-, and 25%-part load) - [24,55] Water Transport Factor WTF…”
Section: Coefficient Of Performance Copmentioning
confidence: 99%
“…Figure 9: Ventilation system with inverter equipped in metro stations (adapted from [66]). A recent study has used DX A/C and evaporative condensers together in UMSs [67],…”
Section: Variable Frequency Devices (Vfds)mentioning
confidence: 99%
“…Additionally, the condensing temperature can be decreased due to direct expansion, hence increasing the system's CoP. An economic model has been applied to analyze the effect of using this solution in Beijing, and the results showed that it saved energy by up to 81,022 kWh annually, equaling to 11% of the energy consumption by conventional systems [67]. However, the operation performance of this system is affected by the changing external conditions, such as the air relative humidity and velocity on the condenser side, which limits its operational stability.…”
Section: Direct Expansion Air-conditioning (Dx A/c)mentioning
confidence: 99%
“…The comparison showed that with a 72% relative humidity, nearly 9% energy, could be saved by the application of the evaporative cooler [7]. Overall, evaporative cooling has been the most widely applied and well-studied approach in condenser cooling technology, and various numerical models and experiments have validated its ability to improve the COP of RAC systems [8][9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%