Design and Evaluation of Self-Microemulsifying Drug Delivery System (SMEDDS) of Tacrolimus

Abstract: Abstract. The objective of present investigation was to formulate self-microemulsifying drug delivery systems (SMEDDS) of tacrolimus (FK 506), a poorly water soluble immunosuppressant that exhibits low and erratic bioavailability. Solubility of FK 506 in various oils, surfactants cosurfactants and buffers was determined. Phase diagrams were constructed at different ratios of surfactant/cosurfactant (K m ) to determine microemulsion existence region. The effect of oil content, pH of aqueous phase, dilution, and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
68
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 109 publications
(71 citation statements)
references
References 21 publications
2
68
1
Order By: Relevance
“…The mean particle sizes, reported as the z-average based on mean intensity, were shown in Table 2. There was no significant difference in particle size among PEG 114 -b-PBC 8 , PEG 114 -b-PBC 17 , and PEG 114 -b-PBC 30 , the particle size range was from 65 to 75 nm. The morphology and particle size of micelles formed by PEG-b-PBC was determined by TEM ( Figure 5), which showed a uniform size distribution with average diameter below 50 nm, which is a little smaller than the z-average diameters obtained by DLS.…”
Section: Preparation and Characterization Of Micellesmentioning
confidence: 79%
See 4 more Smart Citations
“…The mean particle sizes, reported as the z-average based on mean intensity, were shown in Table 2. There was no significant difference in particle size among PEG 114 -b-PBC 8 , PEG 114 -b-PBC 17 , and PEG 114 -b-PBC 30 , the particle size range was from 65 to 75 nm. The morphology and particle size of micelles formed by PEG-b-PBC was determined by TEM ( Figure 5), which showed a uniform size distribution with average diameter below 50 nm, which is a little smaller than the z-average diameters obtained by DLS.…”
Section: Preparation and Characterization Of Micellesmentioning
confidence: 79%
“…Using the peak areas of PEG CH 2 groups at * 3.6 and those of CH 2 in BC main chain at * 4.3, the degree of polymerization and molecular weight of the polymers was calculated and listed in Table 1. The M n s of PEG-b-PBC polymers with different hydrophobic core lengths determined by 1 H NMR were 7000 g/mol for PEG 114 -b-PBC 8 , 9250 g/mol for PEG 114 -b-PCD 17 , 12,500 g/mol for PEG 114 -b-PBC 30 , respectively. The other characteristics of PEG-b-PBC polymers are summarized in Table 1.…”
Section: Synthesis and Characterization Of Polymersmentioning
confidence: 99%
See 3 more Smart Citations