2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI) 2017
DOI: 10.1109/icpcsi.2017.8392173
|View full text |Cite
|
Sign up to set email alerts
|

Design and development of portable potentiostat for advanced research in electrochemical biosensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…The electrode developed in this study showed comparable performance to that of other electrodes previously developed in different studies. A few research studies, such as those in [ 40 , 45 ], developed electrodes that had linear ranges outside the permissible levels in the water. Furthermore, the electrodes were developed using complicated and multiple preparation and modification steps, such as ball milling [ 47 ], reflux heating for the preparation of zinc-based metal-organic frameworks [ 41 ], and the implementation of numerous materials for detection, such as hemoglobin, Nafion, palladium, and graphene in Ref.…”
Section: Investigation Resultsmentioning
confidence: 99%
“…The electrode developed in this study showed comparable performance to that of other electrodes previously developed in different studies. A few research studies, such as those in [ 40 , 45 ], developed electrodes that had linear ranges outside the permissible levels in the water. Furthermore, the electrodes were developed using complicated and multiple preparation and modification steps, such as ball milling [ 47 ], reflux heating for the preparation of zinc-based metal-organic frameworks [ 41 ], and the implementation of numerous materials for detection, such as hemoglobin, Nafion, palladium, and graphene in Ref.…”
Section: Investigation Resultsmentioning
confidence: 99%
“…Our prototype has also carried out tests for 6 different measurement methods. [3] Unreported USB C8051F005 CV 1 [4] 50 Bluetooth, Wifi ESP 32, Arduino Uno CV, LSV, CA 1 [5] Unreported USB ATxmega32E5 CV, LSV, SWV, ASV, CA 1 [7] Unreported USB ATmega328 LSV 1 [8] 40 USB Arduino Uno CV, LSV, CA 1 [9] 55 USB Arduino Teensy 3.2 CV, LSV, CA, CC 1 [10] Unreported USB STM32F103RCT6 Unreported 1 [19] While in the CA, the graph pattern was appropriate, indicating the same measurement characteristics as the Emstat Pico potentiostat with its module only integrated with the USB module. We can also see that, in general, potentiostats have one measurement channel, while in this study, we show that three measurement channels can be run semi-parallelly.…”
Section: Electrochemical Measurements and Performance Comparisonmentioning
confidence: 99%
“…Ministat, according to research by Adams et al, uses the R environment for the graphical user interface (GUI) [5], while Pansodtee uses Python [6]. In contrast, Bukkawar et al prefer to use Microsoft Excel as the GUI [7]. In addition, instruments to support chemistry learning have been developed specifically for electrochemistry using a similar approach.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The electrochemical equipment is also considerably smaller and more portable. For instance, a hand-held potentiostat that has been commercially available for years . However, more importantly, potential scanning can be modulated using the equipment, such that the measurements can “trace” or “resonate with” the molecular motion of the analyte molecules .…”
mentioning
confidence: 99%