2020
DOI: 10.1109/lra.2019.2958734
|View full text |Cite
|
Sign up to set email alerts
|

Design and Control of a Piezo Drill for Robotic Piezo-Driven Cell Penetration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 19 publications
0
16
0
Order By: Relevance
“…Cell types (such as suspension cells and adherent cells) and cargo properties (such as size, polarity, and morphology) are not limited by this method. The advantages of microinjection technology include precise operation at the micro-nanometer scale (Nadappuram et al, 2019), precise control of injection location and injection volume, high injection success rate, high cell survival rate, and safety (Capecchi, 1980;Dai et al, 2020;Rybouchkin et al, 1995).…”
Section: Individual Injectionmentioning
confidence: 99%
See 2 more Smart Citations
“…Cell types (such as suspension cells and adherent cells) and cargo properties (such as size, polarity, and morphology) are not limited by this method. The advantages of microinjection technology include precise operation at the micro-nanometer scale (Nadappuram et al, 2019), precise control of injection location and injection volume, high injection success rate, high cell survival rate, and safety (Capecchi, 1980;Dai et al, 2020;Rybouchkin et al, 1995).…”
Section: Individual Injectionmentioning
confidence: 99%
“…2d ). It can automatically detect penetrating cell membrane and stop piezo stack in time to reduce cell damage caused by vibration (Dai et al, 2020). The device is structurally designed to meet standard clinical settings and the piezo stack section has also been improved.…”
Section: Penetrating the Barriersmentioning
confidence: 99%
See 1 more Smart Citation
“…In the puncture experiment of mouse oocytes (n=45), the puncture success rate reached 100% and only caused a 3.4 µm deformation of the oocyte during the puncture process. As shown in Figure 9 C , Dai et al 107 installed the piezoelectric actuator next to the holder of the microcapillary by adopting the eccentric configuration of the piezoelectric actuator, which has the advantage of not affecting the installation of the standard microcapillary. At the same time, these authors also developed a technology to correlate filters and motion history images based on angular feature probability data to automatically detect the cell membrane rupture through piezoelectric drilling.…”
Section: Oocyte Micromanipulationmentioning
confidence: 99%
“…(C) Microinjector with piezoelectric actuator eccentric configuration. Adapted with permission from 104 , copyright 2011 Spring Nature, and 106 , copyright 2018 IEEE, and 107 , copyright 2020 IEEE.…”
Section: Figurementioning
confidence: 99%