2009
DOI: 10.1109/tmag.2008.2006564
|View full text |Cite
|
Sign up to set email alerts
|

Design and Characterization of Miniature Auto-Focusing Voice Coil Motor Actuator for Cell Phone Camera Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
21
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 77 publications
(21 citation statements)
references
References 17 publications
0
21
0
Order By: Relevance
“…During AF actuation, the Lorentz force is larger than the sum of the moving part weight and the restoring spring force. Moreover, the spring resistance is in direct proportion to the vertical displacement of the moving part [2]. As a result, such VCM actuators typically have dimensions in the order of 10mm × 10mm × 4.6mm [13].…”
Section: Comparison Of Proposed Auto-focusing Module Andmentioning
confidence: 99%
See 1 more Smart Citation
“…During AF actuation, the Lorentz force is larger than the sum of the moving part weight and the restoring spring force. Moreover, the spring resistance is in direct proportion to the vertical displacement of the moving part [2]. As a result, such VCM actuators typically have dimensions in the order of 10mm × 10mm × 4.6mm [13].…”
Section: Comparison Of Proposed Auto-focusing Module Andmentioning
confidence: 99%
“…Thus, a compact auto-focusing module for AF has to meet demands for reducing both dimension and power consumption. Various AF actuators for phone cameras have been considered by many researches [1][2][3]. In general, there are two types of AF actuators that are used in phone cameras.…”
Section: Introductionmentioning
confidence: 99%
“…However, for nonlinear endomicroscopy, a high numerical aperture (NA) lens with superior achromaticity is required [1,11,12], and this is particularly challenging for a tunable lens [13]. Another way to achieve depth scanning is to directly translate the endomicroscope optics, using technologies such as shape memory alloys (SMA) [14], voice coil motors (VCM) [15], or pneumatic actuation [16]. Among the various technologies, SMA wires have shown promise in extending 2D endoscopic imaging to 3D; by Joule heating, the SMA wire contracts and moves the endomicroscope optics to change the beam focus [14].…”
Section: Introductionmentioning
confidence: 99%
“…The power consumption of the electromagnetic actuator should not exceed the critical temperature (the melting point) of the coil coating or the working temperature of permanent magnets. Among electromagnetic actuators, a voice coil actuator that uses Lorentz force has been studied for various applications such as hard disk drive [9], vibration isolation [5,6], lens focusing [10], high-precision stage [11] and fast-steering mirror [12]. In comparison with a solenoid actuator, the voice coil actuator has a somewhat lesser force capacity but a remarkable linearity between the current and force.…”
Section: Introductionmentioning
confidence: 99%