2021
DOI: 10.1016/j.sna.2021.112877
|View full text |Cite
|
Sign up to set email alerts
|

Design and characterization of a pneumatic muscle actuator with novel end-fittings for medical assistive applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…The PMs were studied for decades from modelling, design, and control [43,44]. The PMs were compliant actuators mimicking human muscles, which were lightweight, had a high power-to-weight ratio, and were compliant [45]. However, there was an inevitable In addition, new driving solutions for joint assistance are also being explored and developed.…”
Section: Actuationmentioning
confidence: 99%
“…The PMs were studied for decades from modelling, design, and control [43,44]. The PMs were compliant actuators mimicking human muscles, which were lightweight, had a high power-to-weight ratio, and were compliant [45]. However, there was an inevitable In addition, new driving solutions for joint assistance are also being explored and developed.…”
Section: Actuationmentioning
confidence: 99%
“…Such seals, for each cable, are ensured by an O-ring ( 8) and an internally drilled set screw ( 9): the cable passes through the set screw whose assembly provides for pushing the O-ring that, in turn, closes the passage of air and applies the necessary contact pressure around the external surface of the cable. Other components of the MKM are the outer (10) and inner (11) tubes of the cylindrical capacitor, two sets of metallic screw-nut-eyelet (12) to connect the cables ( 13) and ( 14) to the foils of the capacitor, the hyper-elastic tube (15), and the braided gauze (16). The overall length of the muscle is equal to 380 m; the length of the active part is equal to 285 mm, while the external diameter of the MKM ends is equal to 36 mm.…”
Section: The Design Of the Mkm Based On The Cylindrical Capacitive Tr...mentioning
confidence: 99%
“…Two voltage power supplies, ( 8) and ( 9), were adopted for the linear position and the pressure transducers, respectively. Two digital voltmeters were employed for measuring the linear position output voltage (10) and the pressure transducers (11).…”
Section: The Mkm Protoypementioning
confidence: 99%
See 1 more Smart Citation
“…The developed actuator was also tested in numerous applications to demonstrate its usefulness. To reduce the overall length and weight of the PAM while maintaining the optimum contraction, Carvalho et al [19] designed innovative end fittings, resulting in a shorter overall length of the muscle. Miniaturized artificial muscles (MPAMs) are the smaller version of PAMs, with the same advantages but a much smaller size and weight, which is intriguing for miniaturized applications, including wearable hand exoskeletons [20], cardiac compression devices, and manipulation tools for minimally invasive surgery [21].…”
Section: Introductionmentioning
confidence: 99%