2016
DOI: 10.1016/j.measurement.2015.09.041
|View full text |Cite
|
Sign up to set email alerts
|

Design and application of fiber Bragg grating (FBG) geophone for higher sensitivity and wider frequency range

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7
2
1

Relationship

2
8

Authors

Journals

citations
Cited by 36 publications
(9 citation statements)
references
References 14 publications
0
9
0
Order By: Relevance
“…e occurrence position, main frequency distribution, MA range, and duration of MS events obtained from the study are of great significance to the research of rock burst mechanism and parameter design of the monitoring system in heading face. Occurrence position determines the layout principle of measuring points of the MS system, the main frequency range determines the sampling frequency of the acquisition instrument and the receiving frequency of the sensor, the maximum value of MA determines the range of the sensor [47], and the duration determines the storage time of a single waveform when the original waveforms are stored.…”
Section: Discussionmentioning
confidence: 99%
“…e occurrence position, main frequency distribution, MA range, and duration of MS events obtained from the study are of great significance to the research of rock burst mechanism and parameter design of the monitoring system in heading face. Occurrence position determines the layout principle of measuring points of the MS system, the main frequency range determines the sampling frequency of the acquisition instrument and the receiving frequency of the sensor, the maximum value of MA determines the range of the sensor [47], and the duration determines the storage time of a single waveform when the original waveforms are stored.…”
Section: Discussionmentioning
confidence: 99%
“…But the length of cable which can transmit the signal from the downhole to the ground is more than 10km, and the impedance is very large, so it may results in voltage signal attenuation. [3] In addition, the electromagnetic interference in the coal mine is more serious [4] , and further it can causes the test signal severely deviates from the original signal, eventually, the analysis result can't reflect the micro-seismic events truly. Therefore, it is very important to design high-precision circuits which can transmit micro-seismic signal in long distance.…”
Section: Figure 1seismic Monitoring In Minesmentioning
confidence: 99%
“…The interrogation principle of the FBG-based acceleration sensor depends on the intensity modulation of narrow line width DFB laser [7,8], when a reflection or transmission spectrum curve of an FBG wavelength shifts due to the strain caused by vibration or acceleration. …”
Section: Fbg-based Micro-seismic Sensormentioning
confidence: 99%